  • If a domain is disabled during restart and is enabled
    afterwards, Health Checks are not started if option
    "Independent Health Check" is enabled.
    

Local fix

  • 1) trigger an ?Independent Health Check? restart manually after
    reboot, by disabling/enabling Health Check in the Load Balancer
    Group
    2) do not enable "Independent Health Check"
    

Problem summary

  • Affected are appliances configured to use Load Balancer Groups
    with the Independent Health Check feature.
    
    When the router starts with an admin-state disabled domain
    containing a Load Balancer Group using Independent Health
    Checks, enabling the domain later does not resume the checks.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IC95849

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    600

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-09-10

  • Closed date

    2013-10-21

  • Last modified date

    2013-11-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R600 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
11 February 2022