IC70495: HOT-STANDBY DATABASE TRAPS WHEN DOING A ROLLFORWARD JOB

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Regular job performing rollforward. Sometimes, standby database
    traps with a stack dump because prefetcher takes wrong current
    object
    pointer.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * HADR standby                                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * If during a restart of the normal roll forward processing on *
    * an                                                           *
    * HADR Standby machine, a drop pending index is processed, a   *
    * trap                                                         *
    * may occur in the prefetcher.                                 *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to v97fp4.                                           *
    ****************************************************************
    

Problem conclusion

  • Fixed at v97fp4.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC70495

  • Reported component name

    DB2 FOR LUW

  • Reported component ID

    DB2FORLUW

  • Reported release

    970

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-08-11

  • Closed date

    2011-04-28

  • Last modified date

    2011-04-28

  • APAR is sysrouted FROM one or more of the following:

    IC66632

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DB2 FOR LUW

  • Fixed component ID

    DB2FORLUW

Applicable component levels

  • R970 PSN

       UP



Document information

More support for: DB2 for Linux, UNIX and Windows

Software version: 9.7

Reference #: IC70495

Modified date: 28 April 2011