  • SCENARIO:
    Run CATIA (AL2 and or AL3 license)
    1. Create a Part
    2. Create a Pad
    3. Add a material (steel, Bronze.....)
    4. Save the CATPart on file system
    5. Close it
    6. Reopen the CATpart
    Problem: ABQMaterialPropertiesCatalog.CATfct is missing.
    Expected Result: The problem should not happen
    

Local fix

  • empty
    

Problem summary

  • SCENARIO:
    Run CATIA (AL2 and or AL3 license)
    1. Create a Part
    2. Create a Pad
    3. Add a material (steel, Bronze.....)
    4. Save the CATPart on file system
    5. Close it
    6. Reopen the CATpart
    Problem: ABQMaterialPropertiesCatalog.CATfct is missing.
    Expected Result: The problem should not happen
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R21 GA level.
    Additional Closure Information:
    Incident Diagnosis:
    ABQMaterialPropertiesCatalog.CATfct is missing when opening a
    CATpart.
    Technical explanation of the defect:
    ABQMaterialPropertiesCatalog.CATfct is missing when opening a
    CATpart.
    Technical explanation of the correction:
    The problem has started because, since R20 SP2 AFC material
    has been added to
    Catalog.CATMaterial. So when ever a material from this
    catalog is applied on any Part, AFC
    material gets instantiated in part document. So when such
    Part document is opening it looks
    for catalog/startup/schema of all features present in the
    document. So it also search for
    catalog/startup of AFC material. But with limited license
    this catalog is not present. So AFC
    material catalog could not be found.
    Now this AFC material catalog is moved from AFC framework to
    GPS framwork. This will ensure
    availability of AFC material catalog with basic license.
    Possible by-pass and/or correction limitation:
    The msg can be ignored. It is not fatal.
    .
    Note about solution on V5R20:
    The solution needs a packaging change which can not be done
    on a service pack level and hence the problem has been fixed
    only on V5R21 level.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE00197

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-09-17

  • Closed date

    2010-12-08

  • Last modified date

    2010-12-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R521 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
08 December 2010