APAR status
Closed as unreproducible in next release.
Error description
Unable to modify PartMaster after Transfer V_Project attribute value remains the old one. PreReq-- A single user listed in two different projects and Organisation. Login 1 -- TEST.TST.TEST , Login 2 -- LCA.LC.LCA 1.Login with Context TEST.TST.TEST 2. Create new Part in Part Editor 3.Lock the part 4. Save Part 5. Transfer Part to other Context 6. Select same user who create the part and new context as LCA.LC.LCA 7. Save the Transfer 8. Logout 7. Login with new Context LCA.LC.LCA 8. Search Part in Part Editor 9. Lock Part 10. Edit Part Attributes 11. Change Part Master attribute and press OK 12. Error message - (Cannot lock the part . It is locked by user. You are not granted permission to process VPMObject.Lock!, because the object does not check the condition) .
Local fix
Problem summary
Unable to modify PartMaster after Transfer V _Project attribute value remains the old one Unable to modify PartMaster after Transfer V_Project attribute value remains the old one. PreReq-- A single user listed in two different projects and Organisation. Login 1 -- TEST.TST.TEST , Login 2 -- LCA.LC.LCA 1.Login with Context TEST.TST.TEST 2. Create new Part in Part Editor 3.Lock the part 4. Save Part 5. Transfer Part to other Context 6. Select same user who create the part and new context as LCA.LC.LCA 7. Save the Transfer 8. Logout 7. Login with new Context LCA.LC.LCA 8. Search Part in Part Editor 9. Lock Part 10. Edit Part Attributes 11. Change Part Master attribute and press OK 12. Error message - (Cannot lock the part . It is locked by user. You are not granted permission to process VPMObject.Lock!, because the object does not check the condition) .
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON : ENOVIA VERSION 5 RELEASE 16. THIS PROBLEM IS NOT REPRODUCIBLE ON : ENOVIA VERSION 5 RELEASE 18 GA level AND ON V5R17SP01, V5R16SP07. .
APAR Information
APAR number
HD55333
Reported component name
ENOVIA LCA NT>X
Reported component ID
569151700
Reported release
516
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-07-26
Closed date
2006-07-28
Last modified date
2006-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ENOVIA LCA NT>X
Fixed component ID
569151700
Applicable component levels
R516 PSN SP51607
UP06/10/03 I 1000