IBM Support

Storwize V7000 and SAN Volume Controller FlashCopy Replication Operations Involving Volumes Greater Than 2TB in Size Will Result in Incorrect Data Being Written to the FlashCopy Target Volume

Flashes (Alerts)


Abstract

If a Storwize V7000 or SAN Volume Controller FlashCopy mapping is started on Volumes greater than 2TB in size, this will result in the FlashCopy operation writing incorrect data to the target Volume. The target Volume will therefore not contain the same data as the source Volume.

Content

An issue has been discovered that will result in incorrect data being written to FlashCopy target Volumes greater than 2TB (2,199,023,255,552 bytes) in size.

Data on the source Volume will be unaffected by this issue. Any FlashCopy replicated Volumes less than 2TB in size will also be unaffected by this issue.

Customers are strongly advised not to perform any FlashCopy operations on Volumes greater than 2TB in size, until the fix has been applied.

Customers should also be aware that any previously created FlashCopy target Volumes greater than 2TB in size will have incorrect data on them, and should be treated as inconsistent with the original source data.

Fix

This issue is fixed by APAR IC76806 in the 6.1.0.9 and 6.2.0.1 PTF releases.

IMPORTANT:

Customers using incremental FlashCopy replication of Volumes greater than 2TB, should be aware that simply installing this fix will not restore consistency between source and target Volumes. Any incremental FlashCopy mappings will need to be deleted and recreated after the fix has been applied, to ensure that all incremental target Volumes are fully re-populated with the correct source Volume data.

Customers with non-incremental FlashCopy mappings greater than 2TB simply need to restart these mappings after the upgrade has been applied, in order to achieve a consistent target Volume copy.


Please refer to the What's new in the IBM System Storage SAN Volume Controller Information Center for more information on SVC Terminology changes.

[{"Product":{"code":"ST3FR7","label":"IBM Storwize V7000"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"6.2","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"Version Independent","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}},{"Product":{"code":"STPVGU","label":"SAN Volume Controller"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"6.2","Platform":[{"code":"","label":"SAN Volume Controller"}],"Version":"4.3;5.1;6.1;6.2","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}},{"Product":{"code":"ST3FR7","label":"IBM Storwize V7000"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"6.2","Platform":[{"code":"","label":"IBM Storwize V7000"}],"Version":"6.1;6.2","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
28 March 2023

UID