Troubleshooting
Problem
This document describes the correct way to configure Solaris MPxIO. Please note that other configurations have been seen to cause IO errors.
Resolving The Problem
SVC (V4.2 and later), Storwize V7000 supports load balancing for MPxIO hosts, if the host type called Target Port Group Support ('TPGS') is used.
The following steps are required to enable load balancing on Solaris MPxIO hosts
- Change the SVC or Storwize V7000 host configuration so that the host type is tpgs
- Install the following patches from SUN
- Solaris 9 - 113039-23 or higher
- Solaris 10 sparc - 138888-01 or higher
- Solaris 10 x86 - 138889-01 or higher
- Check/Set the following parameters in /kernel/drv/scsi_vhci.conf:
- Remove or comment out any lines which match the following:
- Activate the new configuration
- Solaris 9: reboot the Solaris host
- Solaris 10: run "stmsboot -u"
- Verify that the new configuration is active by following these steps:
- Run 'luxadm display /dev/rdsk/cXtYdZs2'
- Check that half of the paths (the ones to the preferred node) are shown as PRIMARY/ONLINE and the other half (the ones to the non-preferred node) are shown as SECONDARY/ONLINE.
- load-balance="round-robin";
auto-failback="enable";
- device-type-scsi-options-list = "IBM 2145", "symmetric-option";
symmetric-option = 0x1000000;
where cXtYdZs2 is a SVC or Storwize V7000 device
Please refer to the What's new in the IBM System Storage SAN Volume Controller Information Center for more information on SVC Terminology changes.
These settings have now been documented in the product documentation, so this technote is not being updated to newer releases of SVC or V7000 software.
[{"Product":{"code":"ST3FR7","label":"IBM Storwize V7000"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"6.2","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"Version Independent","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}},{"Product":{"code":"STPVGU","label":"SAN Volume Controller"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"Not Applicable","Platform":[{"code":"","label":"SAN Volume Controller"}],"Version":"4.3;5.1;6.1;6.2","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}},{"Product":{"code":"ST3FR7","label":"IBM Storwize V7000"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"Not Applicable","Platform":[{"code":"","label":"IBM Storwize V7000"}],"Version":"6.1;6.2","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]
Was this topic helpful?
Document Information
Modified date:
28 March 2023
UID
ssg1S1002938