IBM Support

MF63333 - LIC-INCORROUT MSD scan offset not used

PTF Cover Letter


PTF ( Program Temporary Fixes ) Cover letter


Order this fix

Abstract

LIC-INCORROUT MSD scan offset not used


Pre/Co-Requisite PTF / Fix List

REQ  LICENSED           PTF/FIX  LEVEL

TYPE PROGRAM  RELEASE   NUMBER   MIN/MAX  OPTION
---- -------- --------- -------  -------  ------
PRE  5770999  V7R3M0    MF61066   00/00    0000
CO   5770999  V7R3M0    MF61358   00/00    0000
CO   5770999  V7R3M0    MF61359   00/00    0000



NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels.  This PTF may be a prerequisite
for future PTFs.  By applying this PTF you authorize and agree to the
foregoing.

This PTF is subject to the terms of the 'IBM License Agreement for Machine
Code', the terms of which were provided in a printed document that was
delivered with the machine.

SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.





APAR Error Description / Circumvention

-----------------------------------------------
The MSD scan macro incorrectly uses the -offset parameter
causing the scan to go past the 100%.

CORRECTION FOR APAR MA46251 :
-----------------------------
The MSD scan macro LIC code doesn't take into account that the
offset is into a particular data area like the HvData, or
MsData, or the AsData.
The LIC MSD code was changed to handle the -offset parameter
correctly.

CIRCUMVENTION FOR APAR MA46251 :
--------------------------------
None.


Activation Instructions


None.




Special Instructions


None.


Default Instructions

THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.



Supersedes

PTF/FIX NO(S).  APAR TITLE LINE
--------------  ------------------------------------------------------------
   MF63153      LIC-INCORROUT msdusers -suspend only works 1 time
   MF63001      LIC-MSDMgr performance improvements
   MF62442      LIC-MSDMgr  subset dump improvements
   MF62242      LIC-Base Function to Enable Extensions MSDMgr
   MF62146      LIC-INCORROUT MSDMgr unpredictable when multiple users
   MF62094      LIC-INCORROUT A cancelled copy of a MSD, hangs on the exit
   MF61970      LIC Base Function to Enable Extensions MSDMgr
   MF61874      LIC-INCORROUT MSDMgr hardware page table verify incorrect
   MF61360      LIC-Base Function to Enable Extensions MSDMgr
   MF61128      LIC-INCORROUT MSD scan and base changes
   MF61068      LIC-Base Function to Enable Extensions MSDMgr
   MF61778      LIC-INCORROUT MSDMgr copy progressing very slowly
   MF61463      LIC-INCORROUT MSDMgr allow partial media copy, increase size
   MF61060      LIC-INCORROUT change memory available during a MSD IPL

Summary Information

System..............................  i
Models..............................  
Release.............................  V7R3M0
Licensed Program....................  5770999
APAR Fixed..........................  View details for APAR MA46251
Superseded by:......................  View fix details for PTF MF99213
Recompile...........................  N
Library.............................  QSYS
MRI Feature ........................  NONE
Cum Level...........................  C7283730


IBM i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2020, 2021, 2022 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.3.0","Product":{"code":"SWG60","label":"IBM i"},"Component":"5770999","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}}]

Document Information

Modified date:
11 October 2022