IBM Support

IV72886: ADAPTERTIC RETURNS FALSE POSITIVE FAILURE FOR 10GBE ROCE APPLIES TO AIX 7100-03

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Running diagnostics on the PCIe3 2-Port 10GbE RoCE Adapter
    could return a false postive test failure typically during the
    IO Register test
    

Local fix

Problem summary

  • Running diagnostics on the PCIe3 2-Port 10GbE RoCE Adapter
    could return a false postive test failure typically during the
    IO Register test
    

Problem conclusion

  • Modifification of the function that checks the flash semaphore.
    

Temporary fix

Comments

  • 6100-08 - use AIX APAR IV72939
    6100-09 - use AIX APAR IV72887
    7100-02 - use AIX APAR IV72937
    7100-03 - use AIX APAR IV72886
    

APAR Information

  • APAR number

    IV72886

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2015-04-30

  • Closed date

    2015-04-30

  • Last modified date

    2016-05-11

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U865676

       UP15/05/19 I 1000

PTF to Fileset Mapping



Document information

More support for: AIX Enterprise Edition

Software version: 710

Operating system(s): AIX

Reference #: IV72886

Modified date: 11 May 2016