IBM Support

IV71639: ADDRESS UNREACHABLE NOTIFICATION NOT DELIVERED APPLIES TO AIX 7100-03

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Address unreachable notification is not sent to the SCTP
    application, for the destination IP which is not reachable
    since the beginning of the association.
    

Local fix

Problem summary

  • Address unreachable notification is not sent to the SCTP
    application, for the destination IP which is not reachable
    since the beginning of the association.
    

Problem conclusion

  • SCTP code is modified to send address unreachable notification
    when foreign IP is in uncofirmed state and it is detected as
    not reachable.
    

Temporary fix

Comments

  • 6100-08 - use AIX APAR IV71801
    6100-09 - use AIX APAR IV71581
    7100-02 - use AIX APAR IV71606
    7100-03 - use AIX APAR IV71639
    

APAR Information

  • APAR number

    IV71639

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2015-03-30

  • Closed date

    2015-03-30

  • Last modified date

    2016-05-11

  • APAR is sysrouted FROM one or more of the following:

    IV71581

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U864275

       UP15/05/19 I 1000

PTF to Fileset Mapping



Document information

More support for: AIX Enterprise Edition

Software version: 710

Operating system(s): AIX

Reference #: IV71639

Modified date: 11 May 2016