IBM Support

IV70174: ON FC#EN0S AND FC#EN0W, PING MAY NOT WORK APPLIES TO AIX 7100-03

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Ping may not work when cksum_rx=yes and ipv6_offload=yes
    

Local fix

Problem summary

  • Ping may not work when cksum_rx=yes and ipv6_offload=yes
    

Problem conclusion

  • Appropriate code change was done.
    

Temporary fix

Comments

  • 6100-08 - use AIX APAR IV70459
    6100-09 - use AIX APAR IV69941
    7100-02 - use AIX APAR IV70254
    7100-03 - use AIX APAR IV70174
    

APAR Information

  • APAR number

    IV70174

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2015-02-27

  • Closed date

    2015-02-27

  • Last modified date

    2015-09-30

  • APAR is sysrouted FROM one or more of the following:

    IV69941

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U865693

       UP15/05/19 I 1000

PTF to Fileset Mapping



Document information

More support for: AIX Enterprise Edition

Software version: 710

Operating system(s): AIX

Reference #: IV70174

Modified date: 30 September 2015