IBM Support

IV69115: EN0S/EN0T/ENORRECT ADAPTER FIRMWARE IMAGE DOWNLOAD TO APPLIES TO AIX 7100-03

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • EN0S/EN0T firmware may be downloaded to EN0U/EN0V and vice
    versa when EN0S/EN0T and EN0U/EN0V are updated simultaneously.
    This would change the adapter personality to that of the other
    adapter.
    

Local fix

Problem summary

  • EN0S/EN0T firmware may be downloaded to EN0U/EN0V and vice
    versa when EN0S/EN0T and EN0U/EN0V are updated simultaneously.
    This would change the adapter personality to that of the other
    adapter.
    

Problem conclusion

  • Update to the latest devices.pciex.e4148e1614109204.diag which
    ensures the correct image is available for each adapter.
    

Temporary fix

Comments

  • 6100-08 - use AIX APAR IV70104
    6100-09 - use AIX APAR IV69114
    7100-02 - use AIX APAR IV70315
    7100-03 - use AIX APAR IV69115
    

APAR Information

  • APAR number

    IV69115

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2015-02-02

  • Closed date

    2015-02-02

  • Last modified date

    2015-09-30

  • APAR is sysrouted FROM one or more of the following:

    IV69114

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U862224

       UP15/05/19 I 1000

PTF to Fileset Mapping



Document information

More support for: AIX Enterprise Edition

Software version: 710

Operating system(s): AIX

Reference #: IV69115

Modified date: 30 September 2015