IBM Support

IV67377: WATSON2 PHASE II INTEGRATION APPLIES TO AIX 7100-03

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Addresed 16 byte alignment issue a requirement for VSX enabled
    system, and addressed some issue related to alignment and
    realloc.
    

Local fix

Problem summary

  • Addresed 16 byte alignment issue a requirement for VSX enabled
    system, and addressed some issue related to alignment and
    realloc.
    

Problem conclusion

  • Added code to address
    1. realloc of memaligned blocks while retaining the alignment
    2. tightening of memalign for small blocks to reduce memory use
    3. 16 byte alignment issue addressed
    

Temporary fix

Comments

  • 6100-09 - use AIX APAR IV67474
    7100-03 - use AIX APAR IV67377
    

APAR Information

  • APAR number

    IV67377

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2014-12-01

  • Closed date

    2014-12-01

  • Last modified date

    2015-05-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IV67406 IV67474

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U869614

       UP15/05/20 I 1000



Document information

More support for: AIX Enterprise Edition

Software version: 710

Operating system(s): AIX

Reference #: IV67377

Modified date: 22 May 2015