IBM Support

IV65265: TRCRPT -S <STARTTIME> -R IS NOT REPORTING ANY DATA APPLIES TO AIX 7100-03

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • trcrpt -s <starttime> -r is not providing any output.
    

Local fix

  • Use -Ostarttime instead of -s to capture required trace
    events with -r flag.
    

Problem summary

  • trcrpt -r in conjunction with the -s is not reporting any data.
    

Problem conclusion

  • Appropriate code changes has been done to report data in
    trcrpt -s  -r case.
    

Temporary fix

Comments

  • 6100-09 - use AIX APAR IV65200
    7100-03 - use AIX APAR IV65265
    

APAR Information

  • APAR number

    IV65265

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2014-09-25

  • Closed date

    2014-09-25

  • Last modified date

    2015-05-22

  • APAR is sysrouted FROM one or more of the following:

    IV62888

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U865721

       UP15/05/19 I 1000

PTF to Fileset Mapping



Document information

More support for: AIX Enterprise Edition

Software version: 710

Operating system(s): AIX

Reference #: IV65265

Modified date: 22 May 2015