IV65069: NORMAL MODE OPEN FAILS AFTER DIAGNOSTIC OPEN/CLOSE ON DISK APPLIES TO AIX 7100-03

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • If two threads are opening a disk at the same time and
    one
    of them is using the SC_DIAGNOSTIC flag, it is possible
    to
    experience an unexpected open failure under certain
    timing
    conditions.
    
    This problem has been seen in EMC powerPath environments
    when
    two user processes concurrently try to open the
    hdiskpower
    device and one of its underlying hdisk devices. When this
    problem is hit, powerPath may log EMCP_PATH_DEAD /
    EMCP_BUS_DEAD / EMCP_PATH_ALIVE errors in errpt.
    

Local fix

Problem summary

  • normal mode open call to disk may fail with EACCESS error code
    

Problem conclusion

  • code is modifed to fix the timing issue.
    

Temporary fix

Comments

  • 6100-08 - use AIX APAR IV61602
    6100-09 - use AIX APAR IV65017
    7100-02 - use AIX APAR IV69188
    7100-03 - use AIX APAR IV65069
    

APAR Information

  • APAR number

    IV65069

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2014-09-19

  • Closed date

    2014-09-19

  • Last modified date

    2015-09-30

  • APAR is sysrouted FROM one or more of the following:

    IV61602

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U865814

       UP15/05/19 I 1000

PTF to Fileset Mapping



Document information

More support for: AIX Enterprise Edition

Software version: 710

Operating system(s): AIX

Reference #: IV65069

Modified date: 30 September 2015