IV64441: TRUSS -D OR -D FLAG NOT REPORTING TIME INFORMATION APPLIES TO AIX 6100-08

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • truss -d or -D flag is not reporting time information for
    few calls like read, pread, readv, write, pwrite, etc.,
    

Local fix

Problem summary

  • truss -d or -D flag is not reporting time information for
    few calls like read, pread, readv, write, pwrite, etc.,
    

Problem conclusion

  • Modified the code to report time information for calls like
    read, pread, readv, write, pwrite, etc.,
    

Temporary fix

Comments

  • 6100-08 - use AIX APAR IV64441
    6100-09 - use AIX APAR IV62465
    6100-09 - use AIX APAR IV62465
    7100-02 - use AIX APAR IV64267
    7100-03 - use AIX APAR IV62462
    7100-04 - use AIX APAR IV62482
    

APAR Information

  • APAR number

    IV64441

  • Reported component name

    AIX 610 STD EDI

  • Reported component ID

    5765G6200

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2014-09-02

  • Closed date

    2014-09-02

  • Last modified date

    2016-05-11

  • APAR is sysrouted FROM one or more of the following:

    IV61881

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX 610 STD EDI

  • Fixed component ID

    5765G6200

Applicable component levels

  • R610 PSY U867365

       UP15/01/18 I 1000

PTF to Fileset Mapping



Document information

More support for: AIX Standard Edition

Software version: 610

Operating system(s): AIX

Reference #: IV64441

Modified date: 11 May 2016