IBM Support

IV59784: TIMERS ARE NOT GETTING TRIGGERED IN TIMELY MANNER WITH FOLDING T APPLIES TO AIX 6100-08

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Timers with expiration set for 50 ms are firing after
    one sec with cpu folding enabled.
    

Local fix

Problem summary

  • Timers with 50ms timeout interval are getting triggered after
    1 sec/4 sec delay in rare case as cpu sleep is getting called
    even when  there are active timers on trb chain.
    

Problem conclusion

  • Fixed the code in such a way that cpu folding should not
    happen when there are active timers in their trb list.
    

Temporary fix

Comments

  • 6100-08 - use AIX APAR IV59784
    6100-09 - use AIX APAR IV61484
    6100-09 - use AIX APAR IV61484
    7100-02 - use AIX APAR IV62590
    7100-03 - use AIX APAR IV61486
    7100-04 - use AIX APAR IV61590
    

APAR Information

  • APAR number

    IV59784

  • Reported component name

    AIX 610 STD EDI

  • Reported component ID

    5765G6200

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2014-04-25

  • Closed date

    2014-06-11

  • Last modified date

    2016-05-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IV61484 IV61486 IV61590

Fix information

  • Fixed component name

    AIX 610 STD EDI

  • Fixed component ID

    5765G6200

Applicable component levels

  • R610 PSY U867355