IV57350: DLSYM RETURNS EINVAL WHEN 4.2 BINARIES & OLDER ARE RUN ON AIX6.1 APPLIES TO AIX 7100-03

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Binaries compiled with AIX C/C++ compiler 4.2 release and
    older level encounter a problem in some cases when trying
    to resolve a symbol through a dlsym call. Dlsym fails to
    lookup the symbol and returns an EINVAL.
    
    The binaries geenrated by Aix C/C++ 4.2 and older
    compilers  when run on Aix 6.1 can fail with EINVAL.
    

Local fix

  • Currently no local fix is available
    

Problem summary

  • In a program linked on AIX 4.1 or earlier, calls to dlsym()
    fail with EINVAL.
    

Problem conclusion

  • dlopen related data structures have been populated with
    incorrect values for older binaries,Now it has been fixed in
    such a way that dlopen related data structures should contain
    proper values.
    

Temporary fix

Comments

  • 6100-09 - use AIX APAR IV57344
    6100-09 - use AIX APAR IV57344
    6100-09 - use AIX APAR IV57344
    7100-03 - use AIX APAR IV57350
    7100-04 - use AIX APAR IV57362
    

APAR Information

  • APAR number

    IV57350

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2014-03-24

  • Closed date

    2014-03-24

  • Last modified date

    2016-05-10

  • APAR is sysrouted FROM one or more of the following:

    IV15891

  • APAR is sysrouted TO one or more of the following:

    U866405

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U866405

       UP14/05/22 I 1000



Document information

More support for: AIX Enterprise Edition

Software version: 710

Operating system(s): AIX

Reference #: IV57350

Modified date: 10 May 2016