IBM Support

IV55191: SMIT CHTZ_USER MAY FAIL TO PRE-LOAD FROM THE TZ VARIABLE APPLIES TO AIX 6100-09

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • The problem shows up when the "TZ" variable holds a POSIX
    definition containing a "/" character.
    
    E.g.:
    TZ=NFT-1DFT,M3.5.0/02:00:00,M10.5.0/03:00:00
    
    Running
    # smit chtz_user
    
    then fails to pre-load the entry fields with the current
    values.
    

Local fix

  • No fix possible.
    
    All needed entry fields have to be typed in manually.
    

Problem summary

  • SMIT CHTZ_USER MAY FAIL TO PRE-LOAD FROM THE TZ VARIABLE
    

Problem conclusion

  • Corrected the check for Olson-style TZ strings.
    

Temporary fix

Comments

  • 6100-07 - use AIX APAR IV58370
    6100-08 - use AIX APAR IV52127
    6100-09 - use AIX APAR IV55191
    6100-09 - use AIX APAR IV55191
    6100-09 - use AIX APAR IV55191
    7100-01 - use AIX APAR IV57678
    7100-02 - use AIX APAR IV57142
    7100-03 - use AIX APAR IV55194
    7100-04 - use AIX APAR IV55214
    

APAR Information

  • APAR number

    IV55191

  • Reported component name

    AIX 610 STD EDI

  • Reported component ID

    5765G6200

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2014-02-07

  • Closed date

    2014-02-07

  • Last modified date

    2016-05-10

  • APAR is sysrouted FROM one or more of the following:

    IV52127

  • APAR is sysrouted TO one or more of the following:

    U866367

Fix information

  • Fixed component name

    AIX 610 STD EDI

  • Fixed component ID

    5765G6200

Applicable component levels

  • R610 PSY U861174

       UP14/10/28 I 1000

PTF to Fileset Mapping



Document information

More support for: AIX Standard Edition

Software version: 610

Operating system(s): AIX

Reference #: IV55191

Modified date: 10 May 2016