IBM Support

IV54353: ASSERT IN IGETREF OR IACTIVATE APPLIES TO AIX 6100-09

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • For this problem to occur some sort of I/O error
    should put the file-system in a degraded or
    read-only state.
    Mostly ,in addition, there has to be
    some memory pressure that causes inodes to get
    recycled. (This can be due to a large number
    of inodes being used, or a DR event that
    moves memory away from the LPAR).
    
    System would crash with an assert in iGetRef or
    iActivate.
    

Local fix

Problem summary

  • System crashes in iGetRef or iActivate.
    

Problem conclusion

  • If the inode recycle fails, reset the state of the inode.
    

Temporary fix

Comments

  • 6100-09 - use AIX APAR IV54353
    6100-09 - use AIX APAR IV54353
    6100-09 - use AIX APAR IV54353
    7100-03 - use AIX APAR IV54425
    7100-04 - use AIX APAR IV54530
    

APAR Information

  • APAR number

    IV54353

  • Reported component name

    AIX 610 STD EDI

  • Reported component ID

    5765G6200

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2014-01-21

  • Closed date

    2014-01-21

  • Last modified date

    2016-05-10

  • APAR is sysrouted FROM one or more of the following:

    IV51668

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX 610 STD EDI

  • Fixed component ID

    5765G6200

Applicable component levels

  • R610 PSY U859304

       UP14/05/21 I 1000

PTF to Fileset Mapping



Document information

More support for: AIX Standard Edition

Software version: 610

Operating system(s): AIX

Reference #: IV54353