IBM Support

IV53991: "CFGMGR" COMMAND MAY FAIL TO HANDLE SYSTEM LED CODE OUTPUT APPLIES TO AIX 7100-03

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Running the "cfgmgr" command as RBAC privileged user
    leaves
    LED code "0581" on the systems (virtual) front display.
    

Local fix

  • Run the following commands to add the necessary
    privileges
    
    # setsecattr -c \
    
    innateprivs=+PV_DAC_O,PV_PROC_PRIV,PV_KER_ACCT,PV_DEV_CON
    FIG \
     /usr/sbin/cfgmgr
    # setkst
    

Problem summary

  • Running the "cfgmgr" command as RBAC privileged
    user leaves LED code "0581" on the systems
    (virtual) front display.
    

Problem conclusion

  • Proper privileges are given to the /usr/sbin/cfgmgr
    command.
    

Temporary fix

Comments

  • 6100-07 - use AIX APAR IV53516
    6100-08 - use AIX APAR IV58042
    6100-09 - use AIX APAR IV53893
    6100-09 - use AIX APAR IV53893
    6100-09 - use AIX APAR IV53893
    7100-01 - use AIX APAR IV57687
    7100-02 - use AIX APAR IV57154
    7100-03 - use AIX APAR IV53991
    7100-04 - use AIX APAR IV54211
    

APAR Information

  • APAR number

    IV53991

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2014-01-14

  • Closed date

    2014-01-14

  • Last modified date

    2016-05-10

  • APAR is sysrouted FROM one or more of the following:

    IV53516

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U859727

       UP14/05/22 I 1000

PTF to Fileset Mapping



Document information

More support for: AIX Enterprise Edition

Software version: 710

Operating system(s): AIX

Reference #: IV53991

Modified date: 10 May 2016