IV53369: ERRPT ETHERCHANNEL RECOVERY MESSAGE MISSING APPLIES TO AIX 6100-09

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • An etherchannel without backup adapter with all primary
    adapters in link down state will log ECH_MAIN_CHAN_FAIL.
    When at least one primary adapter gets the link up, the
    etherchannel will be active and running, but there is
    no errpt message.
    That means that looking only into the errpt will lead
    to the wrong conclusion that the etherchannel is still
    down.
    

Local fix

Problem summary

  • An etherchannel without backup adapter with all primary
    adapters in link down state will log ECH_MAIN_CHAN_FAIL.
    When at least one primary adapter gets the link up, the
    etherchannel will be active and running, but there is
    no errpt message.
    That means that looking only into the errpt will lead
    to the wrong conclusion that the etherchannel is still
    down.
    

Problem conclusion

  • Code enhanced to log errpt entries for various etherchannel
    recovery scenarios.
    

Temporary fix

Comments

  • 5300-12 - use AIX APAR IV54361
    6100-07 - use AIX APAR IV58245
    6100-08 - use AIX APAR IV47779
    6100-09 - use AIX APAR IV53369
    6100-09 - use AIX APAR IV53369
    6100-09 - use AIX APAR IV53369
    7100-01 - use AIX APAR IV57553
    7100-02 - use AIX APAR IV57103
    7100-03 - use AIX APAR IV53997
    7100-03 - use AIX APAR IV53997
    7100-04 - use AIX APAR IV54219
    

APAR Information

  • APAR number

    IV53369

  • Reported component name

    AIX 610 STD EDI

  • Reported component ID

    5765G6200

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2013-12-16

  • Closed date

    2013-12-16

  • Last modified date

    2016-05-10

  • APAR is sysrouted FROM one or more of the following:

    IV47779

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX 610 STD EDI

  • Fixed component ID

    5765G6200

Applicable component levels

  • R610 PSY U861286

       UP14/10/28 I 1000

PTF to Fileset Mapping

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLLZP","label":"AIX Standard Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSMV87","label":"AIX 6.1 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMVAX","label":"AIX Express Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSAUMY","label":"IBM AIX Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11Q","label":"AIX 6.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11R","label":"APARs - AIX 7.1 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}}]