IBM Support

IV52796: LPPCHK ERRORS UPDATING TO A NEWER RELEASE FROM AN OLDER APPLIES TO AIX 7100-03

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • The first Broadcom ethernet adapter to use Refactored
    Diagnostics causes this problem.
    During the update to a new release from an older one, an
    error occurs because all the refactored diag ODM classes
    get removed, but not all get added back.
    

Local fix

Problem summary

  • The first Broadcom ethernet adapter to use Refactored
    Diagnostics causes this problem.
    During the update to a new release from an older one, an
    error occurs because all the refactored diag ODM classes
    get removed, but not all get added back.
    

Problem conclusion

  • Correct usr/bos.rte.diag.post_u.sh so that it correctly adds/
    creates the PDiagMcode ODM class.
    

Temporary fix

Comments

  • 6100-07 - use AIX APAR IV58729
    6100-08 - use AIX APAR IV58053
    6100-09 - use AIX APAR IV52697
    6100-09 - use AIX APAR IV52697
    6100-09 - use AIX APAR IV52697
    7100-01 - use AIX APAR IV57698
    7100-02 - use AIX APAR IV57160
    7100-03 - use AIX APAR IV52796
    ž**** PE15/06/01 PTF IN ERROR. SEE APAR IV69043  FOR DESCRIPTION
    

APAR Information

  • APAR number

    IV52796

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2013-12-02

  • Closed date

    2013-12-02

  • Last modified date

    2015-06-01

  • APAR is sysrouted FROM one or more of the following:

    IV52697

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U859825

       UP14/05/22 I 1000

PTF to Fileset Mapping



Document information

More support for: AIX Enterprise Edition

Software version: 710

Operating system(s): AIX

Reference #: IV52796

Modified date: 01 June 2015