IBM Support

IV52697: LPPCHK ERRORS UPDATING TO A NEWER RELEASE FROM AN OLDER APPLIES TO AIX 6100-09

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • The first Broadcom ethernet adapter to use Refactored
    Diagnostics causes this problem.
    During the update to a new release from an older one, an
    error occurs because all the refactored diag ODM classes
    get removed, but not all get added back.
    

Local fix

Problem summary

  • The first Broadcom ethernet adapter to use Refactored
    Diagnostics causes this problem.
    During the update to a new release from an older one, an
    error occurs because all the refactored diag ODM classes
    get removed, but not all get added back.
    

Problem conclusion

  • Correct usr/bos.rte.diag.post_u.sh so that it correctly adds/
    creates the PDiagMcode ODM class.
    

Temporary fix

Comments

  • 6100-07 - use AIX APAR IV58729
    6100-08 - use AIX APAR IV58053
    6100-09 - use AIX APAR IV52697
    6100-09 - use AIX APAR IV52697
    6100-09 - use AIX APAR IV52697
    7100-01 - use AIX APAR IV57698
    7100-02 - use AIX APAR IV57160
    7100-03 - use AIX APAR IV52796
    ž**** PE15/06/01 PTF IN ERROR. SEE APAR IV68961  FOR DESCRIPTION
    

APAR Information

  • APAR number

    IV52697

  • Reported component name

    AIX 610 STD EDI

  • Reported component ID

    5765G6200

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2013-12-02

  • Closed date

    2013-12-02

  • Last modified date

    2015-11-22

Fix information

  • Fixed component name

    AIX 610 STD EDI

  • Fixed component ID

    5765G6200

Applicable component levels

  • R610 PSY U861411

       UP15/11/22 I 1000