IBM Support

IV51304: CEC MONITOR DOES NOT DISPLAY DATA FOR APP APPLIES TO AIX 7100-03

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • If the Pool ID is non-zero or CEC has multiple shared processor
    pools, then topas -C reports the APP data as zero. Customer
    can't monitor APP data using topas -C
    

Local fix

Problem summary

  • If the Pool ID is non-zero or CEC has multiple shared processor
    pools, then topas -C reports the APP data as zero. Customer
    can't monitor APP data using topas -C
    

Problem conclusion

  • topas -C will show the APP in a CEC when its configured with
    multiple poolIDs in the following way,
    " Sum up all the Available Processor Pool in different pool
    configured in the CEC and reporting the same "
    

Temporary fix

Comments

  • 5300-12 - use AIX APAR IV53142
    6100-07 - use AIX APAR IV50678
    6100-08 - use AIX APAR IV57830
    6100-09 - use AIX APAR IV51139
    6100-09 - use AIX APAR IV51139
    6100-09 - use AIX APAR IV51139
    7100-01 - use AIX APAR IV57534
    7100-02 - use AIX APAR IV56979
    7100-03 - use AIX APAR IV51304
    

APAR Information

  • APAR number

    IV51304

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2013-10-24

  • Closed date

    2013-10-24

  • Last modified date

    2014-08-14

  • APAR is sysrouted FROM one or more of the following:

    IV50678

  • APAR is sysrouted TO one or more of the following:

    U866427

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U866427

       UP14/05/22 I 1000



Document information

More support for: AIX Enterprise Edition

Software version: 710

Operating system(s): AIX

Reference #: IV51304