IBM Support

IV51150: PERFSTAT_TAPE_TOTAL SHOWS WRONG OUTPUT ON M/C WITHOUT TAPE. APPLIES TO AIX 6100-09

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Wrong values has been returned by perfstat_tape_total when the
    sample application is run on the machine without tape.
    

Local fix

Problem summary

  • Wrong values has been returned by perfstat_tape_total when the
    sample application is run on the machine without tape.
    

Problem conclusion

  • Return value of the perfstat_tape_total API has been changed to
    give error message when the machine doesn't have tape.
    

Temporary fix

Comments

  • 6100-09 - use AIX APAR IV51150
    6100-09 - use AIX APAR IV51150
    6100-09 - use AIX APAR IV51150
    7100-03 - use AIX APAR IV51321
    

APAR Information

  • APAR number

    IV51150

  • Reported component name

    AIX 610 STD EDI

  • Reported component ID

    5765G6200

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2013-10-21

  • Closed date

    2013-10-21

  • Last modified date

    2014-05-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IV51321

Fix information

  • Fixed component name

    AIX 610 STD EDI

  • Fixed component ID

    5765G6200

Applicable component levels

  • R610 PSY U856004

       UP14/05/21 I 1000

PTF to Fileset Mapping