IBM Support

IV50536: AIX DIAGNOSTICS COMMAND LINE DOWNLOAD PREVIOUS MICROCODE FAILS APPLIES TO AIX 6100-09

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • AIX diag microcode download command line with "previous" option
    did not work on pdisk.
    

Local fix

Problem summary

  • AIX diag microcode download command line with "previous" option
    did not work on pdisk.
    

Problem conclusion

  • Debugged source code, testing alongside a system with 2
    microcode levels (previous, and latest) and found source of
    issue on an extra validation using the level flag. Cleaned the
    code, and re-tested.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV50536

  • Reported component name

    AIX 610 STD EDI

  • Reported component ID

    5765G6200

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2013-10-08

  • Closed date

    2013-10-08

  • Last modified date

    2015-11-22

  • APAR is sysrouted FROM one or more of the following:

    IV50457

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX 610 STD EDI

  • Fixed component ID

    5765G6200

Applicable component levels

  • R610 PSY U861530

       UP15/11/22 I 1000

PTF to Fileset Mapping



Document information

More support for: AIX Standard Edition

Software version: 610

Operating system(s): AIX

Reference #: IV50536

Modified date: 22 November 2015