APAR status
Closed as program error.
Error description
If the name of a File System contains one or more underscore characters '_' and Clustered Watch Folder is enabled on said File System then events that are supposed to be delivered to the sink are never sent.
Local fix
Remove underscore chars from File Systems Names where Clustered System Watch is to be used.
Problem summary
If the name of a File System contains one or more underscore characters '_' and Clustered Watch Folder is enabled on said File System then events that are supposed to be delivered to the sink are never sent.
Problem conclusion
This problem is fixed in 5.1.2.12 To see all Spectrum Scale APARs and their respective Fix solutions refer to page: https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale_ apars.html Benefits of the solution: Removes unintended File System Name restriction. Work around: Remove underscore chars from File Systems Names where Clustered System Watch is to be used. Problem trigger: A File System Name that contains one or more underscore characters. Symptom: Unexpected Results/Behavior Platforms affected: ALL Operating System environments Functional Area affected: Watch Folder Customer Impact: Suggested
Temporary fix
Comments
APAR Information
APAR number
IJ47007
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
512
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-05-25
Closed date
2023-07-19
Last modified date
2023-07-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"512","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
20 July 2023