IJ39049: THRESHOLD SERVICE STUCK IN DISABLED STATE AFTER MMHEALTH CONFIG MONITOR PAUSE/RESUME

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • When running mmhealth config monitor pause,
    followed by a mmhealth config monitor resume,
    the THRESHOLD component will stay in DISABLED state.
    

Local fix

  • Execute the command "mmsysmonc enable thresholds"
    

Problem summary

  • When running mmhealth config monitor pause,
    followed by a mmhealth config monitor resume,
    the THRESHOLD component will stay in DISABLED state.
    

Problem conclusion

  • This problem is fixed in 5.1.2 PTF 4
    To see all Spectrum Scale APARs and
    their respective fix solutions refer to page
    https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale
    apars.html
    
    Benefits of the solution:
    The status of the threshold service by node health
    monitoring with mmhealth command will be reported correctly.
    
    Work around:
    Execute the command "mmsysmonc enable thresholds"
    
    Problem trigger:
    The issue occurs only if the node health monitoring
    was paused and resumed again.
    
    Symptom: Error output/message
    
    Platforms affected: ALL Operating System environments
    
    Functional Area affected: System Health
    
    Customer Impact: Suggested
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ39049

  • Reported component name

    SPEC SCALE STD

  • Reported component ID

    5737F33AP

  • Reported release

    512

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-03-29

  • Closed date

    2022-03-29

  • Last modified date

    2022-03-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SPEC SCALE STD

  • Fixed component ID

    5737F33AP

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"512","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
30 March 2022