Error description

  • Starting in AIX 7.1.5.0 and 7.2.2.0 (RSCT 3.2.3.0), the
    cthags subsystem can fail and exit as a result of an
    underlying failure to successfully query the interface
    states from the CAA layer of AIX.
    
    When this failure occurs, a GS_TS_RETCODE_ER error will
    be logged in the errpt, with a diagnostic explanation
    similar to "hats connection has a problem with
    hb_errno = 1"
    Because cthags is a critical subsystem for PowerHA
    functionality, such a failure will cause the node to
    be shut down to protect resource (data) integrity.
    

Local fix

Problem summary

  • In RSCT 3.2.3.0 and higher, Group Services (cthags) can suffer
    a failure and exit due to an underlying interface state query
    to the CAA layer in AIX.  A failure of this subsystem cannot
    be tolerated by PowerHA or VIOS SSP, and will result in a
    node failure in either cluster type.
    

Problem conclusion

  • With this fix, cthags will register that the error occurred,
    but will adapt to the situation and keep running.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ22296

  • Reported component name

    RSCT FOR AIX

  • Reported component ID

    5765F07AP

  • Reported release

    325

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2020-01-24

  • Closed date

    2020-01-24

  • Last modified date

    2022-01-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RSCT FOR AIX

  • Fixed component ID

    5765F07AP

Applicable component levels

  • R325 PSY U890386

       UP22/01/26 I 1000

PTF to Fileset Mapping