A fix is available
APAR status
Closed as program error.
Error description
Starting in AIX 7.1.5.0 and 7.2.2.0 (RSCT 3.2.3.0), the cthags subsystem can fail and exit as a result of an underlying failure to successfully query the interface states from the CAA layer of AIX. When this failure occurs, a GS_TS_RETCODE_ER error will be logged in the errpt, with a diagnostic explanation similar to "hats connection has a problem with hb_errno = 1" Because cthags is a critical subsystem for PowerHA functionality, such a failure will cause the node to be shut down to protect resource (data) integrity.
Local fix
Problem summary
In RSCT 3.2.3.0 and higher, Group Services (cthags) can suffer a failure and exit due to an underlying interface state query to the CAA layer in AIX. A failure of this subsystem cannot be tolerated by PowerHA or VIOS SSP, and will result in a node failure in either cluster type.
Problem conclusion
With this fix, cthags will register that the error occurred, but will adapt to the situation and keep running.
Temporary fix
Comments
APAR Information
APAR number
IJ22296
Reported component name
RSCT FOR AIX
Reported component ID
5765F07AP
Reported release
325
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2020-01-24
Closed date
2020-01-24
Last modified date
2022-01-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RSCT FOR AIX
Fixed component ID
5765F07AP
Applicable component levels
R325 PSY U890386
UP22/01/26 I 1000
PTF to Fileset Mapping
U886893 rsct.basic.rte 3.2.5.2
U886893 rsct.basic.rte 3.2.5.2
U886893 rsct.basic.rte 3.2.5.2