Direct link to fix
APAR status
Closed as program error.
Error description
STEPS to Reproduce: ================ 1)Install latest PowerHA 2)Configure 127 listeners in listener.ora 3)Add DB Instance to cluster using oracle SA 4)Start the cluster services Cluster is going to ST_RP_FAILED state when oracle DB instance is added with 127 Listeners. and Oracle RG is going to "TEMPORARY ERROR" state.
Local fix
Increase the stabilization interval for Oracle listener monitor as below using clmgr command, Stabilization interval = 180+(30* monitors in Oracle RG)
Problem summary
Oracle RG is going to Temporary ERROR state and Cluster is going to ST_RP_FAILED state when 127 listeners are configured for a DB
Problem conclusion
Made changes to configure stabilization interval of Oracle listener monitor based on number of listeners.
Temporary fix
Increase the stabilization interval for Oracle listener monitor as below using clmgr command, Stabilization interval = 180+(30* monitors in Oracle RG)
Comments
APAR Information
APAR number
IJ17904
Reported component name
POWERHA SYSMIR
Reported component ID
5765H3910
Reported release
723
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2019-07-29
Closed date
2019-12-10
Last modified date
2019-12-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
POWERHA SYSMIR
Fixed component ID
5765H3910
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"723","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSXU4N","label":"PowerHA SystemMirror Enterprise Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"723","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"723","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"723","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
19 October 2021