A fix is available
APAR status
Closed as program error.
Error description
When VSE/POWER startup is haltet by invalid AUTOSTART card, e.g. FORMAT QUEUES= SIR command will show placeholder for VSE/POWER level instead of actual level.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of SIR command * **************************************************************** When SIR command is issued during VSE/POWER startup before VSE/POWER queue file has been opened, VSE/POWER level information will be shown as VSE/POWER 9.4.0 DY-BASE 01/01/1900
Problem conclusion
Code to update VSE/POWER level is now executed by IPW$$I2 before AUTOSTART statements are executed.
Temporary fix
Comments
APAR Information
APAR number
DY47811
Reported component name
VSE/POWER
Reported component ID
5686VS603
Reported release
62C
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-01-30
Closed date
2019-01-31
Last modified date
2019-02-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UD54352
Modules/Macros
IPW$$I2 IPW$$I3
Fix information
Fixed component name
VSE/POWER
Fixed component ID
5686VS603
Applicable component levels
R62C PSY UD54352
UP19/02/06 I 1000
Fix is available