IBM Support

Rational Functional Tester V10.1.0

Download


Abstract

IBM Rational Functional Tester V10.1.0 has been made generally available and contains new features as well as fixes to client-reported and internally found defects.

Download Description

Table of Contents
Sections Description

The Change history section provides an overview on what is new in this release with a description of any new functions or enhancements when applicable.

The How critical is this fix section provides information related to the impact of this release to allow you to assess how your environment may be affected.

The Prerequisites section provides important information to review prior to the installation of this release.

The Download package section provides the direct link to obtain the download package for installation in your environment.

The Installation instructions section provides the installation instructions necessary to apply this release into your environment.

The Known side effects section contains a link to the known problems (open defects) identified at the time of this release.

Supporting Documentation
Document Description

Click to review the detailed system requirements information for a complete list of hardware requirements, supported operating systems, prerequisites and optional supported software, with component-level details and operating system restrictions.

Click to view, browse, and search online information related to the product.

Click to review a complete list of the defects (APARs) resolved in this release including a list of resolved defects for the entire version family.

Find technical developer content and resources.

Prerequisites

Prerequisites include:

Version of IBM Installation Manager required: IBM Installation Manager 1.8.6 or later.

Installation Instructions

Review the installation page in the IBM Product Documentation.

Download Package

Download options
Access type Description

Passport Advantage and Passport Advantage Express clients are required to sign in to download the software package.

If you are entitled for Rational Functional Tester and need to download your software from Passport Advantage, perform the following steps:

  1. Logon to Passport Advantage.
  2. Select Software Downloads and Media Access.
  3. Select the Download Finder.
  4. Select Find by description or part number.
  5. Select the Product Description and All radio buttons and enter Rational Functional Tester in the description field.
  6. Select Continue.
  7. Expand the eAssemblies and you will see your entitled software.

IBM Software Group OEM offerings are designed for partners who develop and sell business solutions with embedded or bundled IBM middleware software. Clients with Flexible Contract Type (FCT) license purchases and IBM Business Partners must sign in to download the software package.

How critical is this fix?

Impact Assessment
Impact Description

This is a full release. It contains new features, as well as fixes for client-reported and internally found defects.

Test Results

Definitions

Regression: An error in the Maintenance Delivery Vehicle (MDV) that produces incorrect or unexpected behavior causing a supported feature to stop functioning as designed.
This includes:

  • Coding errors that cause a regression
  • Documentation or packaging problems that cause a regression
  • Errors reported in a new function delivered in a MDV that cause a regression

Incomplete: An error in the MDV has not regressed, but does not work as designed.
This includes:

  • Fixed APARs which did not solve the original problem but did not break anything new
  • APARs reporting documentation errors, such as readme errors, that cause problems applying an MDV but do not lead to a regression


Notes:
  • Regression and incomplete APARs are considered fix-in-error or MDV-in-error
  • Definitions above apply only to valid APARs that result in product fixes (APARs returned as working-as-designed are not assessed for being fix-in-error)
  • Issues in major releases due to new functionality do not apply in this definition

There are no known regressions to report.

Problems Solved

Defects resolved

Click the Fix List link in the table of contents above to review a list of the problems solved in this release.

Known Side Effects

Review the following list of known issues and open defects:
New to this release
ID Description

TP-67544

When you configure a Web UI test on the UCD server and the Overwrite Results file option is checked in the Edit Properties for Run an IBM Rational Functional Tester – Web UI test window of the Run an IBM Rational Functional Tester – Web UI test step, the results file does not get overwritten during the test run.
TP-62667

When you install Rational Functional Tester V10.1.0 on Red Hat Linux Enterprise 8.0 and later, the installation fails with an error message.
To work around this problem, you must first install libnsl.so.1 on your computer for a successful installation of the product. Alternatively, you can create a soft link from libnsl.so.2 by running the following command on the command-line interface:
sudo ln -s /usr/lib64/libnsl.so.2 /usr/lib64/libnsl.so.1

TP-67053 On Windows, there is an incompatibility between the version of Java packaged with the product (OpenJDK OpenJ9 V1.8.0_252) and AdoptOpenJDK14. To work around this problem, uninstall the AdoptOpenJDK14 product or remove it from the PATH before using the product.
TP-67525

When you rename an encrypted column in the dataset CSV editor, the dataset is renamed but hexadecimal values appear in the encrypted column.
To work around this problem, you must save and close the CSV file after you rename an encrypted column close. You must then open the dataset again so that the encrypted cell is updated with the new name without any data loss.

Previous known issues that still apply
ID Description
TP-64492
When you upgraded the product from V10.0.0 to V10.0.1, and then to V10.0.2.1, you cannot roll back to V10.0.1 of the product. You must uninstall V10.0.2.1, and then install the desired version.
 

If you directly upgraded the product either from V10.0.0 or V10.0.1 to V10.0.2.1, then you can roll back to the previous version of the product, that is, V10.0.0 or V10.0.1. 

The following table illustrates the rollback status when you upgrade the product from previous versions to V10.0.2.1:

Installed version Upgraded path Rollback status
V10.0.0 V10.0.0 > V10.0.1 > V10.0.2.1 Rollback to V10.0.1 and V10.0.0: Failure
V10.0.0 V10.0.0 > V10.0.1 > V10.0.2 > V10.0.2.1 Rollback to V10.0.2: Success
Rollback to V10.0.1 and V10.0.0: Failure
V10.0.0 V10.0.0 > V10.0.2.1 Rollback to V10.0.0: Success
V10.0.1 V10.0.1 > V10.0.2.1 Rollback to V10.0.1: Success
TP-59612 You must install Rational Functional Tester V10.0.2 on Mac OS by using Installation Manager V1.9.1. For more information, see Product installation issues on Mac OS while using IBM Installation Manager V1.9.
TP-68671 Using multiple monitors with workbench running on one monitor and browser on another for an extended view is not supported.

Change History

What's new

Review the Rational Functional Tester 10.1.0 Release Notes for other new features.

Back to top

Off

Technical Support

Tab navigation

IBM Rational Software Support Communities

  • Visit the IBM Support Portal to configure your support portal experience and review FAQs, lists of known problems, fixes, and a wealth of important support information.
     
  • Visit developerWorks to access an online collection of tutorials, sample code, standards, forums and other resources provided by experts at IBM to assist software developers using Rational tools including access to the IBM RFE Community.
     
  • Visit the Jazz Community if you use a Rational product created using the Jazz platform to interact directly with the Jazz development team and other community members, download product trials and betas and track developement progress.

Helpful Hints For Obtaining Technical Assistance:

Before you contact IBM Rational Software Support, gather the background information that you need to describe the problem. When you describe a problem to an IBM software support specialist, be as specific as possible and include all relevant background information so that the specialist can help you solve the problem efficiently. To save time, know the answers to these questions:

  • What software versions were you running when the problem occurred?
  • Do you have logs, traces, or messages that are related to the problem?
  • Can you reproduce the problem? If so, what steps do you take to reproduce it?
  • Is there a workaround for the problem? If so, be prepared to describe the workaround.

If you have helpful information to diagnose or identify the problem on your system, you can provide this data by following the instructions to exchange information with IBM Technical Support.

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSJMXE","label":"IBM Rational Functional Tester"},"ARM Category":[{"code":"a8m0z000000boAoAAI","label":"Documentation->Functional Tester"}],"ARM Case Number":"","Platform":[{"code":"PF016","label":"Linux"},{"code":"PF017","label":"Mac OS"},{"code":"PF033","label":"Windows"}],"Version":"10.1.0","Line of Business":{"code":"LOB45","label":"Automation"}}]

Problems (APARS) fixed
PH15226;PH21395;PH23879;PH10303;PH18668

Document Information

Modified date:
27 July 2020

UID

ibm16228448