IBM Support

Tivoli Log File Agent, Version 6.3.0 Fix Pack 03 (6.3.0-TIV-ITM_LFA-FP0003)

Download


Abstract

This fix pack updates the IBM Tivoli Monitoring framework component, the IBM SDK Java Technology Edition Java Runtime Environment (JRE), and the Java and MS Authenticode certificates.

Download Description

(C) Copyright International Business Machines Corporation 2018.
All rights reserved.

Component: Tivoli® Log File Agent,
     Version 6.3.0
           
Component ID: 5724C04LF

Fix Pack: 0003, 6.3.0-TIV-ITM_LFA-FP0003

Date: October 3, 2018

Contents:

1.0 General description
2.0 Problems fixed
3.0 Architecture and prerequisites
4.0 Image directory contents
5.0 Installation instructions
6.0 Additional installation information
7.0 Known problems and work-arounds
8.0 Additional product information
9.0 Copyright and trademark information
10.0 Notices


1.0 General description
===============
This fix pack updates the IBM Tivoli Monitoring framework component,
the IBM SDK Java Technology Edition Java Runtime Environment (JRE),
and the Java and MS Authenticode certificates.
NOTE: See section 3.0 Architecture and prerequisites.

In addition, it resolves the APARs and defects listed in the
"Problems Fixed" section below and includes the superseded fixes
listed in section 2.4.


2.0 Problems fixed
============
The following problems are addressed by this fix.

  2.1 APARs
  -------------

  APAR: IJ06011
  Abstract: LOG FILE AGENT DETECTS AN EVENT WITH A DIFFERENT FORMAT
        BECAUSE A LOG ENTRY IS TRUNCATED AT THE MIDDLE OF A LINE.
  Additional information: When monitoring a log file along with
        Windows Event logs, a truncated event might be detected with
        an unexpected format or not detected at all, depending on the
        data and formats used. This occurs because multiple lines are
        being read in at one time and the truncated line is all that
        fits in the end of the read buffer. The truncated or partial
        record is then processed as if it was complete.
        The reading of multiple lines, even though there are no multi-
        line formats, is correctly triggered because of the Windows
        Event Log monitoring. However, the truncated or partial record
        should have been saved until the complete line is read in,
        before processing it for a match.

        This is related to changes made for APAR IV82170 in Fix Pack 01.

  2.2 Defects
  --------------
  None.

  2.3 Enhancements
  ----------------------
  Enhancement: 218733
  Abstract: Uplift TEMA, and JRE to v6.2.3 FP5 and certificates
  Additional Information: This fix pack includes updates to the
       following components which might be installed into the
       IBM Tivoli Monitoring installation directory (for example,
       CANDLEHOME), if a higher version does not already exist.

       - IBM Tivoli Monitoring framework (ax/gl) component to version
         6.2.3 Fix Pack 0005.  This raises the prequisite level. See
         section 3.0 Architecture and prerequisites.

       - IBM SDK Java Technology Edition Java Runtime Environment (JRE).
         For all platforms, except PowerPC little-endian,
         the JVM (64-bit) version is: 06.16.65.00.
         For PowerPC little-endian (lpl266), IBM Tivoli Monitoring v6.3.0
         and above, the JVM version is: 07.10.25.00.

       - Updated Java and MS Authenticode (jar) signing certificates.
         These certificates are fully SHA-2.

  2.4 Superseded fixes
  -------------------------
  6.3.0-TIV-ITM_LFA-FP0002
  6.3.0-TIV-ITM_LFA-FP0001
  6.3.0-TIV-ITM_LFA-IF0005
  6.3.0-TIV-ITM_LFA-IF0004
  6.3.0-TIV-ITM_LFA-IF0003
  6.3.0-TIV-ITM_LFA-IF0002
  6.3.0-TIV-ITM_LFA-IF0001
 
  2.5 APARs and defects included from superseded fixes
  ---------------------------------------------------------------
  See 6.3.0-TIV-ITM_LFA-FP0002.README for a complete list of all
  APARs and fixes included from superseded fixes.
 
     
3.0 Architecture and prerequisites
======================
This fix is supported on all operating systems listed in the Tivoli
Log File Agent User's Guide, version 6.3.0.

The following link is for the Tivoli operating system and application
support matrix. Please refer to this matrix for the latest
certification information.
Please refer to the IBM Software Product Compatibility Reports (SPCR)
for the latest operating system certification information:
http://publib.boulder.ibm.com/infocenter/prodguid/v1r0/clarity/index.html

  3.1 Prerequisites for this fix
  --------------------------------
  The prerequisite level for this fix is as follows:
  - IBM Tivoli Monitoring 6.2.3 Fix Pack 5 (6.2.3-TIV-ITM-FP0005)
 
  This fix pack is a complete install image and as such, can be
  installed on a pristine system. This fix is also cumulative, and can
  be installed on any fix level for this version, release, and mod
  level above the prerequisite.

  For details, see the Troubleshooting Wiki:
  https://www.ibm.com/developerworks/mydeveloperworks/wikis/home?lang=en#/wiki/Tivoli%20Monitoring/page/Log%20File%20Agent
 
4.0 Image directory contents
====================
This fix image contains the following files:

-  6.30-TIV-ITM_LFA-FP0003.tar.gz
-  6.30-TIV-ITM_LFA-FP0003.README

5.0 Installation instructions
==================

  5.1 Before installing the fix
  -------------------------------
  - The prerequisites listed under section 3.1 entitled 'Prerequisites
    for this fix' must be installed before this fix can be installed.
    
  - For the purpose of this README, the symbol <CANDLEHOME> is the
    IBM Tivoli Monitoring installation directory. The default value
    for CANDLEHOME is '/opt/IBM/ITM' on UNIX systems and 'C:\IBM\ITM'
    on Windows systems.

  - Before installing this fix on UNIX systems, set the environment
    variable CANDLEHOME to the IBM Tivoli Monitoring installation
    directory.
        
    For example:
    > CANDLEHOME=/opt/IBM/ITM
    > export CANDLEHOME  
 
  - Because there is no uninstall utility for this fix, make sure to
    perform a backup of your environment before installing this fix.

  - NOTE: Before installing the LO x86-64 bit agent, you must
    un-install the WINNT 32-bit version of the agent and the 32/64
    bit compatibility package.


  5.2 Local agent update
  --------------------------
  For installation instructions, see the Log File Agent User's Guide
  v6.3.0:
  http://www.ibm.com/support/knowledgecenter/SSTFXA_6.3.0/com.ibm.itm.doc_6.3/logfile/logfileagent_user.htm?lang=en
 
  Note:
  1. The PowerPC little-endian installation image is located in the
     PPC_LE directory of the installation image. Invoke ./install.sh
     from this directory.

  2. On Windows systems, when the installation completes, the
     Readme.txt displays "Welcome to IBM Tivoli Monitoring V6.2.3 Fix
     Pack 5." This is the installer level and Readme and is not an
     error.

  5.3 Remote agent update
  ----------------------------
  1. Transfer the archive file 6.3.0-TIV-ITM_LFA-FP0003.tar.gz to a
     temporary directory on the IBM Tivoli Enterprise Monitoring
     Server system.  For the purpose of this README, the symbol <TEMP>
     represents the fully qualified path to this directory. Note: On
     Windows systems, this path includes the drive letter.

  2. Expand the archive file using the "tar" command on UNIX systems or
     an extract utility on Windows systems. This step creates a directory
     structure that contains fixes for all of the supported platforms.

  3. To add the agent fix bundles into the remote deploy depot, use
     the "tacmd addBundles" command found in $CANDLEHOME/bin on UNIX
     systems or in %CANDLE_HOME%\bin on Windows systems. For more
     information on the "tacmd addBundles" command, see the IBM Tivoli
     Monitoring Administrator's Guide.

     Note:
     1. The prerequisite Log File Agent bundles must also be in the
     depot, to ensure successful completion of the remote agent update.
     2. The 6.3.0-TIV-ITM_LFA-FP000<n> bundles must be removed from the
     depot, using the "tacmd removeBundles" command.
     For example: tacmd removeBundles -t lo -v 06300000<n>

     On UNIX systems,
     if the fix was expanded to <TEMP>/KLO_DVD-201809270938-82701:
     > $CANDLEHOME/bin/tacmd addBundles -n
                             -i <TEMP>/KLO_DVD-201809270938-82701
     
     On Windows systems,
     if the fix was expanded to <TEMP>\KLO_DVD-201809270938-82701:
     > %CANDLE_HOME%\bin\tacmd addBundles -n
                              -i <TEMP>\KLO_DVD-201809270938-82701
     
       where:
         -n indicates that prerequisite bundles are not automatically
            added. The -n parameter must be used because the fix
            directory does not contain any prerequisites that the fix
            might require.  Please see Section 3.1 for the prerequisites
            for this fix.
         -i is the directory that contains the deployment bundles to be
          added to the depot.

  4. To log in to the Tivoli Enterprise Monitoring server, and deploy
     the fix to the appropriate nodes where the agent is running, use
     the following "tacmd" commands.  For more information on the
     "tacmd login" and "tacmd updateAgent" commands, see the IBM Tivoli
     Monitoring Administrator's Guide.

     On UNIX systems:
     > $CANDLEHOME/bin/tacmd login -s <server>
                                   -u <itmuser>
                                   -p <password>
                                   
     > $CANDLEHOME/bin/tacmd listSystems
          
     The output shows the Managed System Name for the OS agent on the
     remote system to be updated. Use this value as the target of the
     "tacmd updateAgent" command.
     
     > $CANDLEHOME/bin/tacmd updateAgent -t lo
                                         -n <Managed system name>
                                         -v 06300300

     On Windows systems:
     > %CANDLE_HOME%\bin\tacmd login -s <server>
                                     -u <itmuser>
                                     -p <password>
                                    
     > %CANDLE_HOME%\bin\tacmd listSystems
          
     The output shows the Managed System Name for the OS agent on the
     remote system to be updated. Use this value as the target of the
     "tacmd updateAgent" command.
     
     > %CANDLE_HOME%\bin\tacmd updateAgent -t LO
                                           -n <Managed system name>    
                                           -v 06300300
                              
     Note:
     - The component (-t) for the "tacmd updateAgent" command is
       specified as two characters (LO), not three characters (KLO).
     - The node (-n) for the "tacmd updateAgent" command is the managed
       system name of the operating system (OS) agent to be updated.
       The target node for the "tacmd updateAgent" command is always
       an OS agent.

  5.4 Agent support update
  ------------------------------
  Fix pack 6.3.0-TIV-ITM_LFA-FP0003 includes new certificates
  in the agent support files which need to be installed. If you have
  already installed these updates, there are no additional installation
  steps. Otherwise, install the updates to the Tivoli Enterprise
  Monitoring Server, Tivoli Enterprise Portal Server, or Tivoli
  Enterprise Portal Desktop. For more information about installing
  application support, see Installing and enabling application support
  in the IBM Tivoli Monitoring Installation and Setup Guide.
 
6.0 Additional installation information
========================

  6.1 Installation instructions for agent baroc file
  -----------------------------------------------------
  There are no updates to the baroc files included in this fix or any
  of the superseded fixes.  No additional installation steps are
  required.
 
  6.2 Verifying the update
  ----------------------------
  1. To verify the agent was updated correctly, use the "tacmd" command
     to view the agent's current version after the agent is restarted.
     You are required to log in to a Tivoli Enterprise Monitoring
     Server prior to viewing the agent version.  
                 
     For example:
     On UNIX systems, where $CANDLEHOME is the IBM Tivoli Monitoring
     installation directory, the default location is '/opt/IBM/ITM'.   
    
     > $CANDLEHOME/bin/tacmd login -s <server>
                                   -u <itmuser>
                                   -p <password>

     > $CANDLEHOME/bin/tacmd listSystems -t LO

     On Windows systems, where %CANDLE_HOME% is the IBM Tivoli
     Monitoring installation directory, the default location
     is 'C:\IBM\ITM'.   

     > %CANDLE_HOME%\bin\tacmd login -s <server>
                                     -u <itmuser>
                                     -p <password>
                                     
     > %CANDLE_HOME%\bin\tacmd listSystems -t LO

     Note: The component (-t) for the "tacmd listSystems" command is
     specified as two characters (LO), not three characters (KLO).

     When the agent update is successful, the agent version is:
     06.30.03.00.
    
     After the agent is restarted, you can also use the GUI to verify
     the agent was successfully updated.
    
     For the agent on Windows systems, the version number is
     06.30.03.00.                                         

  2. To verify all the agent components were updated correctly, use
     the "cinfo" command on Linux or UNIX systems or the "kincinfo"
     command on Windows systems. The sample output below shows the
     minimum versions of IBM Tivoli Monitoring framework component,
     IBM SDK Java Technology Edition Java Runtime Environment (JRE),
     and the LO component versions of the Tivoli Enterprise Portal
     Server, Tivoli Enterprise Monitoring Server, and Tivoli
     Enterprise Portal Desktop  after this fix pack has been
     successfully installed.
     
     Note: The displayed date of the build might not be accurate. This
     is a known problem.      
                            
     On UNIX or Linux systems (except PowerPC little-endian):
     ---------------------------------------------------------
     To validate that all components have been installed, run the
     following command:

     ./cinfo -i    
     
     For example:
     > $CANDLEHOME/bin/cinfo -i

     *********** Wed Sep 27 23:42:54 WST 2018 ******************
     User: root Groups: root ...                       
     Host name : linux100     Installer Lvl:06.23.05.00
     CandleHome: /opt/IBM/ITM
     ***********************************************************
     ...Product inventory

     ax      IBM Tivoli Monitoring Shared Libraries
              li6263  Version: 06.23.05.00

     gs      IBM GSKit Security Interface
              li6243  Version: 07.40.47.00

     jr      Tivoli Enterprise-supplied JRE
              li6263  Version: 06.16.65.00

     lo      Tivoli Log File Agent
              li6263  Version: 06.30.03.00

     ui      Tivoli Enterprise Services User Interface
              li6263  Version: 06.23.05.00

 
     On PowerPC little-endian systems:
     ---------------------------
     # /opt/IBM/ITM/bin/cinfo -i

     *********** Wed Sep 27 11:50:10 EDT 2018 ******************
     User: root Groups: root
     Host name : ppcLe01      Installer Lvl:06.30.07.00
     CandleHome: /opt/IBM/ITM
     ***********************************************************
     ...Product inventory

     ax      IBM Tivoli Monitoring Shared Libraries
              lpl266  Version: 06.30.07.00

     gs      IBM GSKit Security Interface
              lpl266  Version: 08.00.50.69

     jr      Tivoli Enterprise-supplied JRE
              lpl266  Version: 07.10.25.00

     lo      Tivoli Log File Agent
              lpl266  Version: 06.30.03.00

     lz      Monitoring Agent for Linux OS
              lpl266  Version: 06.30.07.00

     ui      Tivoli Enterprise Services User Interface
              lpl266  Version: 06.30.07.00

 
     On Windows systems:
     ---------------------
     To validate that all components have been installed, run the
     following command:

     kincinfo -i
    
     For example:
     > %CANDLE_HOME%\InstallITM\kincinfo -i   
     ********* Wednesday, September 27, 2018 11:53:04 AM *********
     User       : admin                 Group     : NA
     Host Name  : WINSERVER             Installer : Ver: 062305000
     CandleHome : C:\IBM\ITM
     Installitm : C:\IBM\ITM\InstallITM
     *************************************************************
     ...Product Inventory

     IN        Install INS/Windows Install Component
               WINNT Version: 06.23.05.00 Build: 201402060625

     IN        TEMA(32-bit) INS/ITM 6.x Agent Install Component
               WINNT Version: 06.23.05.00 Build: 201402060625

     IN        TEMA(64-bit) INS/ITM 6.x Agent Install Component Extensions
               WINNT Version: 06.23.05.00 Build: 201402060625

     AC        KAC(64-bit) CMA/32/64 Bit Agent Compatibility Package
               WIX64 Version: 06.23.05.00 Build: 201402060625

     GL        KGL(64-bit) CMA/Tivoli Enterprise Monitoring Agent Framework
               WIX64 Version: 06.23.05.00 Build: d4099a

     GL        KGL(32-bit) CMA/Tivoli Enterprise Monitoring Agent Framework
               WINNT Version: 06.23.05.00 Build: d4099a

     GS        KGS(64-bit) GSK/IBM GSKit Security Interface
               WIX64 Version: 07.40.47.00 Build: d4029a

     GS        KGS(32-bit) GSK/IBM GSKit Security Interface
               WINNT Version: 07.40.47.00 Build: d4029a

     IN        KIN(32-bit) INS/IBM Tivoli Base Windows Installer
               WINNT Version: 06.23.05.00 Build: 201402060625

     JM        KJM(32-bit) JVM/Embedded JVM
               WINNT Version: 05.09.00.00 Build: d0111a

     JM        KJM(64-bit) JVM/Embedded JVM
               WIX64 Version: 06.16.65.00 Build: 201806061413

     LO        KLO(64-bit) CMA/Tivoli Log File Agent
               WIX64 Version: 06.30.03.00 Build: 201809271341

     LO        TEMS App Support/Tivoli Log File Agent
               WINNT Version: 06.30.03.00 Build: 201809271341

     LO        TEPS App Support/Tivoli Log File Agent
               WINNT Version: 06.30.03.00 Build: 201809271341

     LO        TEPB App Support/Tivoli Log File Agent
               WINNT Version: 06.30.03.00 Build: 201809271341

     LO        TEPD App Support/Tivoli Log File Agent
               WINNT Version: 06.30.03.00 Build: 201809271341

     UI        KUI(32-bit) CLI/Tivoli Enterprise Services User Interface
               WINNT Version: 06.23.05.00 Build: 201402060625

     Note: For additional updates to the JM component, see section 7.0
           Known problems and workarounds.
          
  3. To verify the agent you are running contains the updates from the
     fix, see the following lines in the agent log                    
     <hostname>_lo_<instance>_kloagent_<timestamp>.log located in
     $CANDLEHOME/logs on UNIX systems and
     %CANDLE_HOME%\tmaitm6\logs on Windows systems:

     <timestamp>       Component: ira
     <timestamp>          Driver: agent_fac_63:201809261709/...
     <timestamp>       Timestamp: Sep 26 2018 ...
 

7.0 Known problems and work-arounds
=========================

  - Problem: After installing the fix pack on Windows systems with an
        IBM Tivoli Monitoring v6.2.3 FPnn base install, an obsolete
        KJM(32-bit) JVM/Embedded JVM is not updated nor removed.

        For example, the cinfo output shows:
        JM        KJM(32-bit) JVM/Embedded JVM
                  WINNT Version: 05.09.00.00 Build: d0111a

    Work-around: Install the IBM Tivoli Monitoring 6 JRE Update
           (6.X.X-TIV-ITM_JRE_CANDLEHOME-20180726) to update
           obsolete 32-bit JVM component to the latest PSIRT
           version/level.
        

8.0 Additional product information
======================
None.


9.0 Copyright and trademark information
==================================  
A current list of IBM trademarks is available on the Web at "Copyright
and trademark information" at www.ibm.com/legal/copytrade.shtml.


10.0 Notices
=======
INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION
"AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Some jurisdictions do not allow disclaimer of express or implied
warranties in certain transactions, therefore, this statement may not
apply to you.

This information could include technical inaccuracies or typographical
errors. Changes are periodically made to the information herein; these
changes will be incorporated in new editions of the publication. IBM
may make improvements and/or changes in the product(s) and/or the
program(s) described in this publication at any time without notice.

Microsoft, Windows, and Windows Server are trademarks of Microsoft
Corporation in the United States, other countries, or both.

Java and all Java-based trademarks and logos are trademarks or
registered trademarks of Oracle and/or its affiliates.

UNIX is a registered trademark of The Open Group in the United States
and other countries.

Linux is a registered trademark of Linus Torvalds in the United States,
other countries, or both.

Other company, product, or service names may be trademarks or service
marks of others.

Third-Party License Terms and Conditions, Notices and Information
-----------------------------------------------------------------
The license agreement for this product refers you to this file for
details concerning terms and conditions applicable to third party
software code included in this product, and for certain notices and
other information IBM must provide to you under its license to
certain software code. The relevant terms and conditions, notices and
other information are provided or referenced below. Please note that
any non-English version of the licenses below is unofficial and is
provided to you for your convenience only. The English version of the
licenses below, provided as part of the English version of this file,
is the official version.

Notwithstanding the terms and conditions of any other agreement you
may have with IBM or any of its related or affiliated entities
(collectively "IBM"), the third party software code identified below
are "Excluded Components" and are subject to the following terms and
conditions:

- the Excluded Components are provided on an "AS IS" basis
- IBM DISCLAIMS ANY AND ALL EXPRESS AND IMPLIED WARRANTIES AND
  CONDITIONS WITH RESPECT TO THE EXCLUDED COMPONENTS, INCLUDING, BUT
  NOT LIMITED TO, THE WARRANTY OF NON-INFRINGEMENT OR INTERFERENCE
  AND THE IMPLIED WARRANTIES AND CONDITIONS OF MERCHANTABILITY AND
  FITNESS FOR A PARTICULAR PURPOSE
- IBM will not be liable to you or indemnify you for any claims
  related to the Excluded Components
- IBM will not be liable for any direct, indirect, incidental,
  special, exemplary, punitive or consequential damages with respect
  to the Excluded Components.

 

Prerequisites

 The prerequisite level for this fix is as follows:
  - IBM Tivoli Monitoring 6.2.3 Fix Pack 5 (6.2.3-TIV-ITM-FP0005)
 
  This fix pack is a complete install image and as such, can be
  installed on a pristine system. This fix is also cumulative, and can
  be installed on any fix level for this version, release, and mod
  level above the prerequisite.

[{"PRLabel":"6.2.3-TIV-ITM-FP0005","PRLang":"English","PRSize":"\t3.73 GB","PRPlat":{"label":"AIX","code":"PF002"},"PRURL":"https://www-01.ibm.com/support/docview.wss?uid=swg24035801"}]

Installation Instructions

Please refer to the full README contained in the Download Description section above for general installation instructions.

On
[{"DNLabel":"6.3.0-TIV-ITM_LFA-FP0003","DNDate":"09 Oct 2018","DNLang":"English","DNSize":"2586,332131","DNPlat":{"label":"AIX","code":"PF002"},"DNURL":"http://www.ibm.com/support/fixcentral/quickorder?fixids=6.3.0-TIV-ITM_LFA-FP0003&product=ibm/Tivoli/IBM Tivoli Monitoring&source=dbluesearch&platform=All","DNURL_FTP":" ","DDURL":null}]
[{"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"Tivoli Log File Agent","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"6.3.0.1;6.3.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Product Synonym

log adapter, logfile

Document Information

Modified date:
08 October 2018

UID

ibm10734043