IBM Support

PI44686: ICKDSF PPRCOPY QUERY COMMAND DOES NOT RETURN THE INFORMATION FORTHE DEVICE AS A PRIMARY WHEN DEVICE IS CASCADED.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When device is cascaded the ICKDSF PPRCOPY QUERY command may
    only return the information for the device as a secondary via
    The following message:
    ICK02215I INFORMATION FOR THIS VOLUME AS A SECONDARY FOLLOWS
    
    The information for the device as a primary may be missing. The
    message that should be displayed along with the primary
    information is as following:
    ICK02214I INFORMATION FOR THIS VOLUME AS A PRIMARY FOLLOWS
    
    The pathing information may also be missing. An example of
    pathing information follows:
    PATHS  SAID/DEST        STATUS  DESCRIPTION
    -----  ---------        ------  ----------------
    1      0230 0300        13      ESTABLISHED FIBRE CHANNEL PATH
    
    Also message ICK03096I EXISTING VTOC IS LOCATED AT CCHH=X'cccc
    hhhh' AND IS   xxxxx TRACKS will now be displayed when using the
    INIT command if a VTOC already exists. The format 4 DSCB
    identifier in the old VTOC will be invalidated if the VTOC has
    been placed in a different location. This function was
    originally provided in apar PI25913 but was disabled and will
    now be enabled via this apar.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of the ICKDSF INIT, REFORMAT and       *
    *                 PPRCOPY QUERY commands.                      *
    ****************************************************************
    * PROBLEM DESCRIPTION: The INIT command has been modified so   *
    *                      that if a VTOC already exists it will   *
    *                      print a message telling the location    *
    *                      and size of the existing VTOC, and will *
    *                      invalidate the format 4 DSCB identifier *
    *                      in the old VTOC if the new VTOC has     *
    *                      been placed in a different location.    *
    *                                                              *
    *                      The PPRCOPY QUERY command is not        *
    *                      printing out the primary volume         *
    *                      information for cascaded volumes that   *
    *                      do not support multi target pprc.       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The information for the device as a primary will now be printed
    out for cascaded volumes when using the PPRCOPY QUERY command.
    

Problem conclusion

  • See ++HOLD(ENH) and ++HOLD(DOC) text for additional info.
     KEYWORDS: PPRC/K
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI44686

  • Reported component name

    ICKDSF

  • Reported component ID

    565899201

  • Reported release

    H01

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2015-07-09

  • Closed date

    2015-09-15

  • Last modified date

    2015-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI31159 UI31160 UI31161 UI31162 UI31163

Modules/Macros

  • ICKDV11  ICKRC01
    

Publications Referenced
GC35003342    

Fix information

  • Fixed component name

    ICKDSF

  • Fixed component ID

    565899201

Applicable component levels

  • RHCD PSY

       UP

  • RH01 PSY UI31160

       UP15/09/24 P F509

  • RH03 PSY

       UP

  • RH14 PSY UI31159

       UP15/09/23 P 1509

  • R1NM PSY UI31161

       UP15/09/23 I 1000

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.