Family 7063+02 IBM Hardware Management Console based on POWER technology

IBM United States Sales Manual
Revised: May 25, 2021


Table of contents
Product life cycle datesProduct life cycle datesTechnical descriptionTechnical description
AbstractAbstractPublicationsPublications
HighlightsHighlightsFeaturesFeatures
DescriptionDescriptionAccessoriesAccessories
ModelsModelsSuppliesSupplies


Product life cycle dates

Top rule

Type Model Announced Available Marketing Withdrawn Service Discontinued
7063-CR2 2021-04-13 2021-05-21 - -


Back to topBack to top

Abstract

Top rule

The Power HMC (7063-CR2) is a dedicated rack-mounted workstation that helps you to configure and manage system resources on Power servers using POWER7, POWER8, or POWER9 technology-based processors. The HMC connects to one or more managed systems to perform the following primary functions:

  • Provide a console for system administrators and service providers to manage server hardware
  • Deliver basic virtualization management through support for configuring logical partitions (LPARs) and dynamic resource allocation, including processor and memory settings
  • Detect, report, and store changes in hardware conditions
  • Act as a service focal point for service providers to determine an appropriate service strategy
  • Display operating system session terminals for each partition
  • Provide the call home focal point for managed servers
  • Display ASMI menus for managed servers

The HMC also supports advanced service functions, including guided repair and verify, concurrent firmware updates for managed systems, and around-the-clock error reporting with Electronic Service Agent for faster support.

The HMC is delivered with its machine code preinstalled on the HDD. After the HMC is installed and connected to a managed system, you can perform system management tasks.

The HMC machine code does not have provisions for loading or running additional applications that are not related to hardware management or service. All of the tasks needed to maintain the managed system, the underlying operating system, and the HMC machine code are available by using the HMC management interface.

IBM offers integration of the Power HMC into racks before shipping.
Note: IBM also offers the Power Systems virtual HMC (vHMC) as a software-based alternative to the HMC appliance. The vHMC software is delivered in the form of a prebuilt virtual machine (VM) that can be downloaded and deployed on IBM PowerVM or various x86 virtualization platforms. The vHMC software is updated in alignment with updates to the HMC appliance.

Due to client demand, HMC 9.2 code is now available for 7042-CR9 HMC. HMC 9.2 will be the last supported HMC code release for 7042-CR9. POWER9 servers with 950 firmware (FW950) or later, if managed by a Hardware Management Console (HMC), require either the x86 based HMC, 7042-CR9, POWER based HMC, 7063-CR1 or later; or the HMC Virtual Appliance, 5765-HMW (x86 based) or 5765-HMB (POWER based) or later. For additional information refer to the HMC Support Matrix.

Model abstract 7063-CR2

IBM Power Systems Hardware Management Console delivers an appliance based on POWER9 technology for increased deployment flexibility when managing Power Systems server.



Back to topBack to top

Highlights

Top rule

The IBM Power Systems Hardware Management Console (HMC), based on POWER technology, is a dedicated-function device used solely for the control and service functions of IBM Power Systems servers. It is designed to deliver management support for Power servers using IBM POWER7, IBM POWER8, or IBM POWER9 technology-based processors.

The HMC has the following standard hardware attributes:

  • 1U base configuration
  • POWER9 130W 6c CPU
  • 64 GB (4 x 16 GB) or 128 GB (4 x 32 GB) of DDR4 system memory
  • 2 x 1.8 TB SAS SFF 2.5-inch hard disk drive (HDD) RAID 1
  • Rail bracket option for round-hole rack mounts
  • Two USB 3.0 hub ports in the front of the server (option to remove)
  • Two USB 3.0 hub ports in the rear of the server
  • Redundant 900W power supplies
  • 4 x 1 Gb Ethernet ports
  • 2 x 10 Gb Ethernet Ports on optional PCI adapter
  • 1 x 1 Gb baseboard management controller (BMC) Ethernet port


Back to topBack to top

Description

Top rule

The IBM Power Systems HMC (7063-CR2), based on POWER9 technology, is a dedicated rack-mounted workstation that allows clients to configure and manage system resources on Power Systems servers using POWER7, POWER8, or POWER9 processors. The HMC provides basic virtualization management through support for configuring logical partitions (LPARs) and dynamic resource allocation, including processor and memory settings for selected Power Systems servers. The HMC also supports advanced service functions, including guided repair and verify, concurrent firmware updates for managed systems, and around-the-clock error reporting with Electronic Service Agent for faster support.

Clients can use Power Systems HMCs in combination with other hardware based HMCs or virtual HMCs.

Reliability, Availability, and Serviceability

Not applicable.

Section 508 of the US Rehabilitation Act

Hardware Management Console is capable as of May 21, 2021, when used in accordance with associated IBM documentation, of satisfying the applicable standards, including the Worldwide Consortium Web Content Accessibility Guidelines, European Standard EN 301 349, and US Section 508, provided that any assistive technology used with the product properly interoperates with it. An Accessibility Conformance Statement can be requested on the Product accessibility information website.



Back to topBack to top

Models

Top rule

Model summary matrix

Model Processor Speed Memory Hard Drive CD-ROM
CR2 6-cores 3.0 GHz 64 GB 2 x 1.8 TB SAS N/A

Customer setup (CSU)

Yes.

Devices supported

Not applicable.

Model conversions

Not available.



Back to topBack to top

Technical description

Top rule

Physical specifications Physical specifications Hardware requirements Hardware requirements
Operating environment Operating environment Software requirements Software requirements
Limitations Limitations


Physical specifications

  • Width: 434.10 mm (17.1 in.)
  • Depth: 726.76 mm (28.6 in.)
  • Height: 43.71 mm (1.7 in.)
  • Weight: 17.6 kg (38.8 lb)

To assure installability and serviceability in non-IBM industry- standard racks, review the installation planning information for any product-specific installation requirements.

Operating environment

For some standards and guidelines about the operating environment, see the ASHRAE-A2 website.

Limitations

  • The HMC is a dedicated-function device used only for the control and service functions of the Power servers. It is not available for use as a general purpose computing resource.
  • The HMC requires a minimum HMC code level. This code level restricts the HMC to management of POWER7, POWER8, or POWER9 servers.

Integrated repair and verify for CRUs is available at this time in English only. Clients who want access to the translated services guides will be directed to an external website from their HMC.

If additional assistance is required with interpreting English repair and verify:

  • Contact the IBM Hardware Support Center (using the method you would normally use to obtain support for your hardware), and ask for Hardware Support. Be sure to have your HMC machine type and serial number available. Indicate that you have problems with translated repair and verify.
  • An IBM Service Support Representative (SSR) may be dispatched to your site to assist with your repair and verify activity.
  • The HMC and attached servers may not be accessible to you while the SSR is working.

Hardware requirements

The IBM Power Systems HMC requires a minimum HMC code level V9R2M950. This code level restricts the CR2 model to management of POWER7, POWER8, or POWER9 servers. If you need redundant HMC function, the servers can be attached to two separate HMCs to address availability requirements. All HMCs must have the same level of HMC Licensed Machine Code installed.

Management of multiple servers from an HMC might require the use of an Ethernet hub, which provides a physical connection from the HMC to each server rather than a logical Ethernet connection over a LAN. IBM Knowledge Center provides information about classic and enhanced GUIs for configuring and operating single or multiple managed systems.

Software requirements

The following web browsers are supported for connection with the HMC Licensed Machine Code V9R2M950:

  • Microsoft Internet Explorer 1082.18362.0.
  • Firefox (version 82.0.1 (64-bit).
  • Chrome 86.0.4240.111 (Official Build) (64-bit) and Java 8 Runtime Environment are supported.
  • Safari (Versions 14.0 and 12.0.5)

The following web browsers are supported for connection with the OpenPower BMC:

  • Chrome version 60
  • Firefox version 52.1.2
  • Microsoft Internet Explorer version 11
  • Safari version 10.1.2


Back to topBack to top

Publications

Top rule

No publications are shipped with the announced products.

To access the IBM Publications Center Portal, go to the IBM Publications Center website.

The Publications Center is a worldwide central repository for IBM product publications and marketing material with a catalog of 70,000 items. Extensive search facilities are provided. A large number of publications are available online in various file formats, which can currently be downloaded.



Back to topBack to top

Features

Top rule

Features - No charge Features - No charge Feature descriptions Feature descriptions
Features - Chargeable Features - Chargeable Feature exchanges Feature exchanges
Feature availability matrix Feature availability matrix


Features - No charge

None.

Features - Chargeable

Special Features - Initial Orders
  • Administrative
    • (#ESC5) -S&H-a
  • Languages
    • (#9300) -Language Group Specify - US English
    • (#9700) -Language Group Specify - Dutch
    • (#9703) -Language Group Specify - French
    • (#9704) -Language Group Specify - German
    • (#9705) -Language Group Specify - Polish
    • (#9706) -Language Group Specify - Norwegian
    • (#9707) -Language Group Specify - Portuguese
    • (#9708) -Language Group Specify - Spanish
    • (#9711) -Language Group Specify - Italian
    • (#9712) -Language Group Specify - Canadian French
    • (#9714) -Language Group Specify - Japanese
    • (#9715) -Language Group Specify - Traditional Chinese (Taiwan)
    • (#9716) -Language Group Specify - Korean
    • (#9718) -Language Group Specify - Turkish
    • (#9719) -Language Group Specify - Hungarian
    • (#9720) -Language Group Specify - Slovakian
    • (#9721) -Language Group Specify - Russian
    • (#9722) -Language Group Specify - Simplified Chinese (PRC)
    • (#9724) -Language Group Specify - Czech
    • (#9725) -Language Group Specify - Romanian
    • (#9726) -Language Group Specify - Croatian
    • (#9727) -Language Group Specify - Slovenian
    • (#9728) -Language Group Specify - Brazilian Portuguese
    • (#9729) -Language Group Specify - Thai
  • Miscellaneous
    • (#9069) -HMC/Server Order Linkage Indicator
    • (#9461) -Month Indicator
    • (#9462) -Day Indicator
    • (#9463) -Hour Indicator
    • (#9464) -Minute Indicator
    • (#9465) -Qty Indicator
    • (#9466) -Countable Member Indicator
    • (#EBZ0) -Front of Panel without USB ports
    • (#EBZ1) -Front of Panel with 2x USB ports
    • (#EBZ2) -Front of Panel without USB ports - OEM
    • (#EBZ3) -Front of Panel with 2x USB ports - OEM
  • Power
    • (#EB2L) -AC Power Supply - 900W
  • Specify Codes
    • (#4650) -Rack Indicator-Not Factory Integrated One and only one rack indicator feature is required onall orders (#4650 to #4666).
    • (#9169) -Order Routing Indicator-System Plant
    • (#ELG2) -IBM Power Private Cloud Rack Solution Indicator
Special Features - Plant and/or Field Installable
  • Adapters
    • (#EN0W) -PCIe2 2-port 10/1GbE BaseT RJ45 Adapter
  • Administrative
    • (#B0VH) -SP HDR/MR POWER 3Y
    • (#ESC0) -S&H - No Charge
    • (#B0LP) -SP Warranty and Maintenance 5Y 24x7 Same Day ORT
    • (#B0PR) -SP Hard Drive/Media Retention - Power 5 years
    • (#B0UW) -SP Warranty and Maintenance 3Y 24x7 Same Day ORT
    • (#B0VH) -SP Hard Drive/Media Retention - Power 3 years
  • Disk
    • (#EHMD) -1.8 TB 10K RPM 4K SAS HDD SFF
  • Linecords
    • (#6458) -Power Cord 4.3m (14-ft), Drawer to IBM PDU (250V/10A)
    • (#6460) -Power Cord 4.3m (14-ft), Drawer To OEM PDU (125V, 15A)
    • (#6469) -Power Cord 4.3m (14-ft), Drawer to Wall/OEM PDU (250V/ 15A) U. S.
    • (#6470) -Power Cord 1.8m (6-ft), Drawer to Wall (125V/15A)
    • (#6471) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/ 10A)
    • (#6472) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/ 16A)
    • (#6473) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/ 10A)
    • (#6474) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/ 13A)
    • (#6475) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/ 16A)
    • (#6476) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/ 10A)
    • (#6477) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/ 16A)
    • (#6478) -Power Cord 2.7 M(9-foot), To Wall/OEM PDU, (250V, 16A)
    • (#6488) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (125V/ 15A or 250V/10A )
    • (#6493) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/ 10A)
    • (#6494) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/ 10A)
    • (#6496) -Power Cord 2.7M (9-foot), To Wall/OEM PDU, (250V, 10A)
    • (#6577) -Power Cable - Drawer to IBM PDU, 200-240V/10A
    • (#6651) -Power Cord 2.7M (9-foot), To Wall/OEM PDU, (125V, 15A)
    • (#6659) -Power Cord 2.7M (9-foot), To Wall/OEM PDU, (250V, 15A)
    • (#6660) -Power Cord 4.3m (14-ft), Drawer to Wall/OEM PDU (125V/ 15A)
    • (#6665) -Power Cord 2.8m (9.2-ft), Drawer to IBM PDU, (250V/10A)
    • (#6669) -Power Cord 4.3M (14-foot), Drawer to OEM PDU, (250V, 15A)
    • (#6671) -Power Cord 2.7M (9-foot), Drawer to IBM PDU, 250V/10A
    • (#6672) -Power Cord 2M (6.5-foot), Drawer to IBM PDU, 250V/10A
    • (#6680) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/ 10A)
    • (#ELC5) -Power Cable - Drawer to IBM PDU (250V/10A)
  • Memory
    • (#EM62) -16 GB DDR4 Memory
    • (#EM63) -32 GB DDR4 Memory
  • Miscellaneous
    • (#0004) -EMEA Bulk MES Indicator
    • (#0964) -Hardware Management Console License for CR2
    • (#0983) -US TAA Compliance Indicator
    • (#0984) -Product assembled in USA manufacturing plant
    • (#1140) -Custom Service Specify, Rochester Minn, USA
    • (#EB2T) -RAID1 Enabled
    • (#ECSM) -Custom Service Specify, Mexico
    • (#ECSP) -Custom Service Specify, Poughkeepsie, USA
  • Processor
    • (#EP75) -6-core 3.0 GHz POWER9 Processor
  • Rack Related
    • (#ERK0) -Fixed Length Rail Kit for 7063-CR2
    • (#ERK1) -Adjustable Length Rail Kit for 7063-CR2
  • Services
    • (#0010) -One CSC Billing Unit
    • (#0011) -Ten CSC Billing Units
  • Specify Codes
    • (#4651) -Rack Indicator, Rack #1
    • (#4652) -Rack Indicator, Rack #2
    • (#4653) -Rack Indicator, Rack #3
    • (#4654) -Rack Indicator, Rack #4
    • (#4655) -Rack Indicator, Rack #5
    • (#4656) -Rack Indicator, Rack #6
    • (#4657) -Rack Indicator, Rack #7
    • (#4658) -Rack Indicator, Rack #8
    • (#4659) -Rack Indicator, Rack #9
    • (#4660) -Rack Indicator, Rack #10
    • (#4661) -Rack Indicator, Rack #11
    • (#4662) -Rack Indicator, Rack #12
    • (#4663) -Rack Indicator, Rack #13
    • (#4664) -Rack Indicator, Rack #14
    • (#4665) -Rack Indicator, Rack #15
    • (#4666) -Rack Indicator, Rack #16

Feature availability matrix

The following feature availability matrix for MT 7063 uses the letter "A" to indicate features that are available and orderable on the specified models. "S" indicates a feature that is supported on the new model during a model conversion; these features will work on the new model, but additional quantities of these features cannot be ordered on the new model; they can only be removed. "N" indicates that the feature is not supported on the new model and must be removed during the model conversion. As additional features are announced, supported, or withdrawn, this list will be updated. Please check with your Marketing Representative for additional information.

        |C| A = AVAILABLE  S = SUPPORTED
        |R| N = NOT SUPPORTED, MUST BE REMOVED
        |2|
        | |
FEAT/PN | |        DESCRIPTION
--------|-|----------------------------------------------------------

0004    |A| EMEA Bulk MES Indicator
0010    |A| One CSC Billing Unit
0011    |A| Ten CSC Billing Units
0964    |A| Hardware Management Console License for CR2
0983    |A| US TAA Compliance Indicator
0984    |A| Product assembled in USA manufacturing plant
1140    |A| Custom Service Specify, Rochester Minn, USA
One and only one rack indicator feature is required on
all orders (#4650 to #4666).
4650    |A| Rack Indicator- Not Factory Integrated
4651    |A| Rack Indicator, Rack #1
4652    |A| Rack Indicator, Rack #2
4653    |A| Rack Indicator, Rack #3
4654    |A| Rack Indicator, Rack #4
4655    |A| Rack Indicator, Rack #5
4656    |A| Rack Indicator, Rack #6
4657    |A| Rack Indicator, Rack #7
4658    |A| Rack Indicator, Rack #8
4659    |A| Rack Indicator, Rack #9
4660    |A| Rack Indicator, Rack #10
4661    |A| Rack Indicator, Rack #11
4662    |A| Rack Indicator, Rack #12
4663    |A| Rack Indicator, Rack #13
4664    |A| Rack Indicator, Rack #14
4665    |A| Rack Indicator, Rack #15
4666    |A| Rack Indicator, Rack #16
6458    |A| Power Cord 4.3m (14-ft), Drawer to IBM PDU (250V/10A)
6460    |A| Power Cord 4.3m (14-ft), Drawer To OEM PDU (125V, 15A)
6469    |A| Power Cord 4.3m (14-ft), Drawer to Wall/OEM PDU (250V/15A)
        | |U. S.
6470    |A| Power Cord 1.8m (6-ft), Drawer to Wall (125V/15A)
6471    |A| Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/10A)
6472    |A| Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/16A)
6473    |A| Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/10A)
6474    |A| Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/13A)
6475    |A| Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/16A)
6476    |A| Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A)
6477    |A| Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/16A)
6478    |A| Power Cord 2.7 M(9-foot), To Wall/OEM PDU, (250V, 16A)
6488    |A| Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (125V/15A
        | |or 250V/10A )
6493    |A| Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A)
6494    |A| Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A)
6496    |A| Power Cord 2.7M (9-foot), To Wall/OEM PDU, (250V, 10A)
6577    |A| Power Cable - Drawer to IBM PDU, 200-240V/10A
6651    |A| Power Cord 2.7M (9-foot), To Wall/OEM PDU, (125V, 15A)
6659    |A| Power Cord 2.7M (9-foot), To Wall/OEM PDU, (250V, 15A)
6660    |A| Power Cord 4.3m (14-ft), Drawer to Wall/OEM PDU (125V/15A)
6665    |A| Power Cord 2.8m (9.2-ft), Drawer to IBM PDU, (250V/10A)
6669    |A| Power Cord 4.3M (14-foot), Drawer to OEM PDU, (250V, 15A)
6671    |A| Power Cord 2.7M (9-foot), Drawer to IBM PDU, 250V/10A
6672    |A| Power Cord 2M (6.5-foot), Drawer to IBM PDU, 250V/10A
6680    |A| Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A)
9069    |A| HMC/Server Order Linkage Indicator
9169    |A| Order Routing Indicator- System Plant
9300    |A| Language Group Specify - US English
9461    |A| Month Indicator
9462    |A| Day Indicator
9463    |A| Hour Indicator
9464    |A| Minute Indicator
9465    |A| Qty Indicator
9466    |A| Countable Member Indicator
9700    |A| Language Group Specify - Dutch
9703    |A| Language Group Specify - French
9704    |A| Language Group Specify - German
9705    |A| Language Group Specify - Polish
9706    |A| Language Group Specify - Norwegian
9707    |A| Language Group Specify - Portuguese
9708    |A| Language Group Specify - Spanish
9711    |A| Language Group Specify - Italian
9712    |A| Language Group Specify - Canadian French
9714    |A| Language Group Specify - Japanese
9715    |A| Language Group Specify - Traditional Chinese (Taiwan)
9716    |A| Language Group Specify - Korean
9718    |A| Language Group Specify - Turkish
9719    |A| Language Group Specify - Hungarian
9720    |A| Language Group Specify - Slovakian
9721    |A| Language Group Specify - Russian
9722    |A| Language Group Specify - Simplified Chinese (PRC)
9724    |A| Language Group Specify - Czech
9725    |A| Language Group Specify - Romanian
9726    |A| Language Group Specify - Croatian
9727    |A| Language Group Specify - Slovenian
9728    |A| Language Group Specify - Brazilian Portuguese
9729    |A| Language Group Specify - Thai
B0VH    |A| SP HDR/MR POWER 3Y
B0LP    |A| SP Warranty and Maintenance 5Y 24x7 Same Day ORT
B0PR    |A| SP Hard Drive/Media Retention - Power 5 years
B0UW    |A| SP Warranty and Maintenance 3Y 24x7 Same Day ORT
B0VH    |A| SP Hard Drive/Media Retention - Power 3 years
EB2L    |A| AC Power Supply - 900W
EB2T    |A| RAID1 Enabled
EBZ0    |A| Front of Panel without USB ports
EBZ1    |A| Front of Panel with 2x USB ports
EBZ2    |A| Front of Panel without USB ports - OEM
EBZ3    |A| Front of Panel with 2x USB ports - OEM
ECSM    |A| Custom Service Specify, Mexico
ECSP    |A| Custom Service Specify, Poughkeepsie, USA
EHMD    |A| 1.8 TB 10K RPM 4K SAS HDD SFF
ELC5    |A| Power Cable - Drawer to IBM PDU (250V/10A)
ELG2    |A| IBM Power Private Cloud Rack Solution Indicator
EM62    |A| 16 GB DDR4 Memory
EM63    |A| 32 GB DDR4 Memory
EN0W    |A| PCIe2 2-port 10/1GbE BaseT RJ45 Adapter
EP75    |A| 6-core 3.0 GHz POWER9 Processor
ERK0    |A| Fixed Length Rail Kit for 7063-CR2
ERK1    |A| Adjustable Length Rail Kit for 7063-CR2
ESC0    |A| S&H - No Charge
ESC5    |A| S&H-a

Feature descriptions


Note: Not all of the following features are available in all countries. Check with your country representative for specific feature availability.

The following is a list of all feature codes in numeric order for the IBM Power Systems 7063 machine type.

Attributes, as defined in the following feature descriptions, state the interaction of requirements among features.

Minimums and maximums are the absolute limits for a single feature without regard to interaction with other features. The maximum valid quantity for MES orders may be different than for initial orders. The maximums listed below refer to the largest quantity of these two possibilities.

The order type defines if a feature is orderable only on initial orders, only on MES orders, on both initial and MES orders, or if a feature is supported on a model due to a model conversion. Supported features cannot be ordered on the converted model, only left on or removed from the converted model.

(#0004) - EMEA Bulk MES Indicator

NON-AAP BULK ORDER INDICATOR

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 9999 (Initial order maximum: )
  • OS level required:
  • Initial Order/MES/Both/Supported: MES
  • CSU: Yes
  • Return parts MES: Does not apply
(#0010) - One CSC Billing Unit

One Billing Unit used by the Customer Solution Center.

  • Attributes provided: One CSC Billing Unit
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 9999 (Initial order maximum: 250)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#0011) - Ten CSC Billing Units

Ten Billing Units used by the Customer Solutions Center.

  • Attributes provided: Ten CSC Billing Units
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 9999 (Initial order maximum: 250)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#0964) - Hardware Management Console License for CR2
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#0983) - US TAA Compliance Indicator

This feature indicates that the product was assembled in a manufacturing plant in the USA or in a country approved under the US Trade Agreement Act. Only valid on U.S. orders.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#0984) - Product assembled in USA manufacturing plant

This feature indicates that the product was assembled in a manufacturing plant in the USA.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#1140) - Custom Service Specify, Rochester Minn, USA

Having #1140 on the order, will cause the order to be routed to Rochester and the machine to be internally routed to the CSC build area in building 114 (Rochester).

  • Attributes provided: Customization
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 9999 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply

One and only one rack indicator feature is required onall orders (#4650 to #4666).

(#4650) - Rack Indicator- Not Factory Integrated

This indicator is used to specify that the rack mountable device in this initial order should not be merged into a rack within IBM Manufacturing. If a device with 4650 is ordered with a rack, the device will not be factory integrated in the ordered rack and will ship uninstalled in the rack.
Note: This "no additional charge" feature will be placed on an initial order for a rack mountable device by the Configuration Tool when the order does not ship from IBM Manufacturing in a Rack. This server is not designed to be rack shippable.

  • Attributes provided: System will not be shipped in a rack.
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
    Note: Only one rack indicator feature is allowed on all orders (#4650).
(#4651) - Rack Indicator, Rack #1

When added to an initial rack order, this indicator is used to specify the first rack for a multi rack order, or the only rack for a single rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #1.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack Integration/ Rack Specify
  • Attributes required: Rack
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#4652) - Rack Indicator, Rack #2

When added to an initial rack order, this indicator is used to specify the second rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #2 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack Integration/Rack specify
  • Attributes required: Rack
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#4653) - Rack Indicator, Rack #3

When added to an initial rack order, this indicator is used to specify the third rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #3 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#4654) - Rack Indicator, Rack #4

When added to an initial rack order, this indicator is used to specify the fourth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #4 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#4655) - Rack Indicator, Rack #5

When added to an initial rack order, this indicator is used to specify the fifth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #5 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#4656) - Rack Indicator, Rack #6

When added to an initial rack order, this indicator is used to specify the sixth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #6 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#4657) - Rack Indicator, Rack #7

When added to an initial rack order, this indicator is used to specify the seventh rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #7 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#4658) - Rack Indicator, Rack #8

When added to an initial rack order, this indicator is used to specify the eighth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #8 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#4659) - Rack Indicator, Rack #9

When added to an initial rack order, this indicator is used to specify the ninth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #9 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#4660) - Rack Indicator, Rack #10

When added to an initial rack order, this indicator is used to specify the tenth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #10 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#4661) - Rack Indicator, Rack #11

When added to an initial rack order, this indicator is used to specify the eleventh rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #11 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#4662) - Rack Indicator, Rack #12

When added to an initial rack order, this indicator is used to specify the twelfth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #12 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#4663) - Rack Indicator, Rack #13

When added to an initial rack order, this indicator is used to specify the thirteenth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #13 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#4664) - Rack Indicator, Rack #14

When added to an initial rack order, this indicator is used to specify the fourteenth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #14 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#4665) - Rack Indicator, Rack #15

When added to an initial rack order, this indicator is used to specify the fifteenth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #15 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#4666) - Rack Indicator, Rack #16

When added to an initial rack order, this indicator is used to specify the sixteenth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #16 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6458) - Power Cord 4.3m (14-ft), Drawer to IBM PDU (250V/10A)

Standard IBM rack power cable that goes from the system or I/O drawer to the rack power distribution unit (PDU). Cable has C13 on one end (for C14 power supply connector on system unit or I/O drawer) and C14 on the other end (for IBM PDU C13 receptacle). Note for different length C13/C14 cables see #6671 (2.7M) or #6672 (2.0M).

  • Attributes provided: Power jumper cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6460) - Power Cord 4.3m (14-ft), Drawer To OEM PDU (125V, 15A)

This power cord goes from the system or I/O drawer to the rack OEM power distribution unit or wall socket outlet. Cable has C13 on one end (for C14 power supply connector on system unit or I/O drawer) and plug type #4 (NEMA 5-15) on the other end.

The following countries/regions use the #6460 power cord to power the system and/or peripheral features requiring a power cord: United States, Antigua & Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Bonaire, Calicos Islands, Canada, Cayman Islands, Colombia, Costa Rica, Cuba, Curacao, Dominican Republic, Ecuador, El Salvador, Guam, Guatemala, Guyana, Haiti, Honduras, Jamaica, Japan, Mexico, Micronesia, Montserrat, Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, St. Kitts/Nevis, St. Martin, Taiwan, Tortola (BVI), Trinidad/Tobago, Venezuela.

  • Attributes provided: Power cord.
  • Attributes required: None.
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6469) - Power Cord 4.3m (14-ft), Drawer to Wall/OEM PDU (250V/15A) U. S.

This power cord goes from the system or I/O drawer to the wall or rack OEM power distribution unit. Cable has C13 on one end (for C14 power supply connector on system unit or I/O drawer) and plug type #5 (NEMA 6-15) on the other end for wall or OEM PDU.

The following countries/regions use the #6469 power cord to power the system and/or peripheral features requiring a power cord:

United States, Anguilla, Antigua & Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Bonaire, Caicos Is., Canada, Cayman Islands, Colombia, Costa Rica, Cuba, Curacao, Dominican Republic, Ecuador, El Salvador, Guam, Guatemala, Haiti, Honduras, Jamaica, Japan, Micronesia, Montserrat, Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, St. Marten NA, Taiwan, Tortola (BVI), Thailand, Venezuela.

  • Attributes provided: Power cord.
  • Attributes required: None.
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6470) - Power Cord 1.8m (6-ft), Drawer to Wall (125V/15A)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #4 (NEMA 5-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 6-foot length.

The following countries/regions use the #6470 power cord to power the system and/or peripheral features requiring a power cord:

United States, Antigua and Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Bonaire, Calicos Islands, Canada, Cayman Islands, Colombia, Costa Rica, Cuba, Curacao, Dominican Republic, Ecuador, El Salvador, Guam, Guatemala, Guyana, Haiti, Honduras, Jamaica, Japan, Mexico, Micronesia, Montserrat, Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, St. Kitts/Nevis, St. Martin, Taiwan, Tortola (BVI), Trinidad/Tobago, Venezuela.

  • Attributes provided: Power cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6471) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/10A)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #73 (InMetro NBR 14136). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.

The following countries/regions use the #6471 power cord to power the system and/or peripheral features requiring a power cord:

Brazil

  • Attributes provided: Power cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6472) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/16A)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #18 (CEE 7 VII). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.

The following countries/regions use the #6472 power cord to power the system and/or peripheral features requiring a power cord:

Afghanistan, Albania, Algeria, Andorra, Angola, Armenia, Austria, Belarus, Belgium, Benin, Bosnia/Herzegovina, Bulgaria, Burkina Faso, Burundi, Cambodia, Cameroon, Cape Verde, Central African Republic, Chad, Comoros, Congo, Croatia, Czech Republic, Dahomey, Djibouti, Egypt, Equatorial Guinea, Eritrea, Estonia, Ethiopia, Finland, France, French Polynesia, French Guyana, Gabon, Georgia, Germany, Greece, Guadeloupe, Guinea, Guinea-Bissau, Hungary, Iceland, Indonesia, Iran, Ivory Coast, Kazakhstan, Kyrgyzstan, Laos, Latvia, Lebanon, Lithuania, Luxembourg, Macau, Macedonia, Mali, Martinique, Mauritania, Mauritius, Mayotte, Moldova, Monaco, Mongolia, Morocco, Mozambique, Netherlands, New Caledonia, Niger, North Korea (C19 only), Norway, Poland, Portugal, Principe, Reunion, Romania, Russia, Rwanda, St. Thomas, Saudi Arabia, Senegal, Serbia, Slovenia, Somalia, South Korea (C19 only), Spain, Surinam, Sweden, Syria, Tahiti, Tajikistan, Togo, Tunisia, Turkey, Turkmenistan, Ukraine, Upper Volta, Uzbekistan, Vanuatu, Vietnam, Wallis & Futuna, Zaire, Zimbabwe.

  • Attributes provided: Power cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6473) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/10A)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #19 (CEE). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.

The following countries/regions use the #6473 power cord to power the system and/or peripheral features requiring a power cord:

Denmark

  • Attributes provided: Power cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6474) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/13A)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #23 (BS 1364A). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.

The following countries/regions use the #6474 power cord to power the system and/or peripheral features requiring a power cord:

Abu Dhabi, Bahrain, Botswana, Brunei, Channel Islands, Cyprus, Dominica, Gambia, Grenada, Grenadines, Guyana, Hong Kong, Iraq, Ireland, Jordan, Kenya, Kuwait, Liberia, Malawi, Malaysia, Malta, Myanmar, Nigeria, Oman, Qatar, Sierra Leone, Singapore, St. Kitts, St. Lucia, Seychelles, Sudan, Tanzania, Trinidad & Tobago, United Arab Emirates, United Kingdom, Yemen, Zambia

  • Attributes provided: Power cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6475) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/16A)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #32 (SII 32-1971). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.

The following countries/regions use the #6475 power cord to power the system and/or peripheral features requiring a power cord:

Israel

  • Attributes provided: Power cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6476) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #24 (SEV 24507). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.

The following countries/regions use the #6476 power cord to power the system and/or peripheral features requiring a power cord:

Lichtenstein, Switzerland

  • Attributes provided: Power cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6477) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/16A)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #22 (SABS 164). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.

The following countries/regions use the #6477 power cord to power the system and/or peripheral features requiring a power cord:

Bangladesh, LeSotho, Maceo, Maldives, Nambia, Pakistan, Samoa, South Africa, Sri Lanka, Swaziland, Uganda.

  • Attributes provided: Power cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6478) - Power Cord 2.7 M(9-foot), To Wall/OEM PDU, (250V, 16A)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #25 (CEI 23-16). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6478 power cord to power the system and/or peripheral features requiring a power cord: Chile Italy Libya

  • Attributes provided: Power cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6488) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (125V/15A or 250V/10A)

This power cord goes from the system and/or peripheral features to a wall-type outlet. 125V, 15A or 250V, 10A, Plug Type #2. Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.

The following countries/regions use the #6488 power cord to power the system and/or peripheral features requiring a power cord:

Argentina, Paraguay, Uruguay.

  • Attributes provided: Power cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6493) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #62 (GB 1053). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.

The following countries/regions use the #6493 power cord to power the system and/or peripheral features requiring a power cord:

People's Republic of China.

  • Attributes provided: Power cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6494) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #69 (IS 6538). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.

The following countries/regions use the #6494 power cord to power the system and/or peripheral features requiring a power cord:

India

  • Attributes provided: Power cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6496) - Power Cord 2.7M (9-foot), To Wall/OEM PDU, (250V, 10A)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #66 (KETI). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6496 power cord to power the system and/or peripheral features requiring a power cord: North Korea South Korea

  • Attributes provided: Power cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6577) - Power Cable - Drawer to IBM PDU, 200-240V/10A

This feature permits manufacturing to select the optimum PDU power jumper cord length (1.0M, 2.0M, 2.7M, or 4.3M) for rack integration. This feature is mandatory on initial order specifying factory integration with IBM racks (such as with 7014-T00 or T42 racks). Feature is not valid on initial order with non-factory integrated feature 4650. Power jumper cord has C13 on one end (for C14 power supply connector on system unit or I/O drawer) and C14 on the other end (for C13 PDU receptacle).
Note: This feature is not used for MES orders except for bulk orders by SDI clients only. See C13/C14 jumper cord features #6458 (4.3M), #6671 (2.7M), #6672 (2.0M) when not using factory integration.

  • Attributes provided: One power jumper cord.
  • Attributes required: At least one rack and the absence of #4650.
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6651) - Power Cord 2.7M (9-foot), To Wall/OEM PDU, (125V, 15A)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #75 (KETI). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6651 power cord to power the system and/or peripheral features requiring a power cord: Taiwan

  • Attributes provided: Power cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6659) - Power Cord 2.7M (9-foot), To Wall/OEM PDU, (250V, 15A)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #76 (KETI). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6659 power cord to power the system and/or peripheral features requiring a power cord: Taiwan

  • Attributes provided: Power cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6660) - Power Cord 4.3m (14-ft), Drawer to Wall/OEM PDU (125V/15A)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #59 (NEMA 5-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 14-foot length.

This power cord meets the DENAN marking requirement in Japan.

  • Attributes provided: Power Cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6665) - Power Cord 2.8m (9.2-ft), Drawer to IBM PDU, (250V/10A)

Standard IBM rack power jumper cord that goes from the system or I/O drawer to the rack power distribution unit (PDU). Cable has C13 on one end (for C14 power supply connector on system unit or I/O drawer) and C20 on the other end (for IBM PDU C19 receptacle).
Note: For power jumper cord which attach to PDUs with C13 receptacles, use features such as #6577, #6458, #6671, or #6672.

  • Attributes provided: Power jumper cord.
  • Attributes required: None.
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6669) - Power Cord 4.3M (14-foot), Drawer to OEM PDU, (250V, 15A)

This power cord goes from the system or I/O drawer to the rack power distribution unit. Plug type #57 (NEMA 6-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 14-foot length. This power cord meets the DENAN marking requirement in Japan.

  • Attributes provided: Power Cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6671) - Power Cord 2.7M (9-foot), Drawer to IBM PDU, 250V/10A

Standard IBM rack power cable that goes from the system or I/O drawer to the rack power distribution unit (PDU). Cable has C13 on one end (for C14 power supply connector on system unit or I/O drawer) and C14 on the other end (for IBM PDU C13 receptacle). Note for different length C13/C14 cables see #6458 (4.3M) or #6672 (2.0M).

  • Attributes provided: Power jumper cord.
  • Attributes required: None.
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6672) - Power Cord 2M (6.5-foot), Drawer to IBM PDU, 250V/10A

Standard rack power cable that goes from the system or I/O drawer to the rack power distribution unit (PDU). Cable has C13 on one end (for C14 power supply connector on system unit or I/O drawer) and C14 on the other end (for IBM PDU C13 receptacle). Note for different length C13/C14 cables see #6458 (4.3M) or #6671 (2.7M).

  • Attributes provided: Power jumper cord.
  • Attributes required: None.
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#6680) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A)

This insulated power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #6 (AS 3112-1964 NZS 198). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.

The following countries/regions use the #6680 power cord to power the system and/or peripheral features requiring a power cord:

Australia, Fiji Islands, Kiribati, Nauru, New Zealand, Papua New Guinea, W. Samoa.

  • Attributes provided: Power cord
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#9069) - HMC/Server Order Linkage Indicator

The HMC/Server order linkage indicate is used to indicator that the HMC is in the same order and should be scheduled for delivery with a server. This order is not a stand-alone HMC order.

  • Attributes provided: HMC order linkage to server order
  • Attributes required: Server order that requires an HMC delivered at the same time
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9169) - Order Routing Indicator- System Plant

This feature will be auto-selected by the Configurator Tool when required. Use of this feature will affect the routing of the order. Selection of this indicator will direct the order to a system plant for fulfillment.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9300) - Language Group Specify - US English

English language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9461) - Month Indicator

This month indicator is used to create a date stamp to enable CFR splitting and rejoining in order to circumvent the AAS maximum limitation of 30 systems entered on any one order. The quantity ordered for this feature is generated by eConfig.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 12 (Initial order maximum: 12)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9462) - Day Indicator

This day indicator is used to create a date stamp to enable CFR splitting and rejoining in order to circumvent the AAS maximum limitation of 30 systems entered on any one order. The quantity ordered for this feature is generated by eConfig.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 31 (Initial order maximum: 31)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9463) - Hour Indicator

This hour indicator is used to create a time stamp to enable CFR splitting and rejoining in order to circumvent the AAS maximum limitation of 30 systems entered on any one order. The quantity ordered for this feature is generated by eConfig.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 24 (Initial order maximum: 24)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9464) - Minute Indicator

This hour indicator is used to create a time stamp to enable CFR splitting and rejoining in order to circumvent the AAS maximum limitation of 30 systems entered on any one order. The quantity ordered for this feature is generated by eConfig.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 60 (Initial order maximum: 60)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9465) - Qty Indicator

This quantity indicator is used to specify the remaining, or N-1 quantity of CFR entities that need to be accumulated for rejoining. The quantity ordered for this feature is generated by eConfig. and is equal to N-1, where 'N' equals the total quantity of CFRs being rejoined.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 9999 (Initial order maximum: 250)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9466) - Countable Member Indicator

This administrative indicator used to identify each CFR associated with a date/time stamp that is eligible for splitting and rejoining. The quantity ordered for this feature is generated by eConfig.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9700) - Language Group Specify - Dutch

Dutch language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9703) - Language Group Specify - French

French language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9704) - Language Group Specify - German

German language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9705) - Language Group Specify - Polish

Polish language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9706) - Language Group Specify - Norwegian

Norwegian language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9707) - Language Group Specify - Portuguese

Portuguese language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9708) - Language Group Specify - Spanish

Spanish language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9711) - Language Group Specify - Italian

Italian language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9712) - Language Group Specify - Canadian French

Canadian French language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9714) - Language Group Specify - Japanese

Japanese language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9715) - Language Group Specify - Traditional Chinese (Taiwan)

Traditional Chinese language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9716) - Language Group Specify - Korean

Korean language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9718) - Language Group Specify - Turkish

Turkish language group for nomenclature and publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9719) - Language Group Specify - Hungarian

Hungarian language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9720) - Language Group Specify - Slovakian

Slovakian language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9721) - Language Group Specify - Russian

Russian language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9722) - Language Group Specify - Simplified Chinese (PRC)

Simplified Chinese language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9724) - Language Group Specify - Czech

Czech language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9725) - Language Group Specify - Romanian

Romanian language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9726) - Language Group Specify - Croatian

Croatian language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9727) - Language Group Specify - Slovenian

Slovenian language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9728) - Language Group Specify - Brazilian Portuguese

Brazilian Portuguese language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#9729) - Language Group Specify - Thai

Thai language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#B0VH) - SP HDR/MR POWER 3Y

ServicePac for Hard Drive or Media Retention for Power 3 years

  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: No
(#B0LP) - SP Warranty and Maintenance 5Y 24x7 Same Day ORT

This feature indicates ServicePac Warranty and Maintenance 5Y 24x7 Same Day ORT

  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Both
  • CSU: N/A
  • Return parts MES: No
(#B0PR) - SP Hard Drive/Media Retention - Power 5 years

This feature indicates Hard Drive/Media Retention - Power 5 years

  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Both
  • CSU: N/A
  • Return parts MES: No
(#B0UW) - SP Warranty and Maintenance 3Y 24x7 Same Day ORT

This feature indicates Warranty and Maintenance 3Y 24x7 Same Day ORT

  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Both
  • CSU: N/A
  • Return parts MES: No
(#B0VH) - SP Hard Drive/Media Retention - Power 3 years

This feature indicates Hard Drive/Media Retention - Power 3 years

  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Both
  • CSU: N/A
  • Return parts MES: No
(#EB2L) - AC Power Supply - 900W

One 100 - 127V or 200 - 240V, 900 watt AC power supply.

To be operational, a minimum power supply in the CEC base enclosure is required. If there is a power supply failure, any of the power supplies can be exchanged without interrupting the operation of the system.

This power supply is not supported on all models.

  • Limitation: Feature EB2L is not available in India.
  • Attributes provided: AC Power Supply
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply
(#EB2T) - RAID1 Enabled

RAID 1 enabled

  • Attributes provided: RAID1 enablement
  • Attributes required: Base disk with the additional #1998 disk. (total of two disk)
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#EBZ0) - Front of Panel without USB ports
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: Yes
  • Return parts MES: Does not apply
(#EBZ1) - Front of Panel with 2x USB ports
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: Yes
  • Return parts MES: Does not apply
(#EBZ2) - Front of Panel without USB ports - OEM
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: Yes
  • Return parts MES: Does not apply
(#EBZ3) - Front of Panel with 2x USB ports - OEM
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU: Yes
  • Return parts MES: Does not apply
(#ECSM) - Custom Service Specify, Mexico

Having #ECSM on the order, will cause the order to be routed to Mexico and the machine to be internally routed to the CSC build area.

  • Attributes provided: Customization
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 9999 (Initial order maximum: 1)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: No
(#ECSP) - Custom Service Specify, Poughkeepsie, USA

Having #ECSP on the order, will cause the order to be routed to Poughkeepsie, USA and the machine to be internally routed to the CSC build area.

  • Attributes provided: Customization
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 9999 (Initial order maximum: 1)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: No
(#EHMD) - 1.8 TB 10K RPM 4K SAS HDD SFF
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#ELC5) - Power Cable - Drawer to IBM PDU (250V/10A)

This feature permits manufacturing to select the optimum PDU power jumper cord length (2.8M or 4.3M) for rack integration. This feature is mandatory for servers that use power supplies with C14 inlets that are going to be factory integrated with IBM racks (such as with 7014-T00 or T42 racks) that contains C19 PDU types.

Feature is not valid on initial order with non-factory integrated feature 4650. Power jumper cord has C13 on one end (for C14 power supply connector on system unit or I/O drawer) and C20 on the other end (for IBM PDU C19 receptacle). MES orders of FC #ELC5 will ship 4.3m length. If MES customers want 2.8m length should order #6665.

  • Attributes provided: Power jumper cord (2.8m or 4.3m)
  • Attributes required: None
  • Minimum required: 0
  • Maximum allowed: 2 (Initial order maximum: 2)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#ELG2) - IBM Power Private Cloud Rack Solution Indicator
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Initial
  • CSU:
  • Return parts MES:
(#EM62) - 16 GB DDR4 Memory

Provides 16 GB of DDR4 system memory.

  • Attributes provided: 16 GB DDR4 memory dimm
  • Attributes required: Available memory slot
  • Minimum required: 0
  • Maximum allowed: 4 (Initial order maximum: 4)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#EM63) - 32 GB DDR4 Memory

Provides 32 GB of DDR4 system memory.

  • Attributes provided: 32 GB DDR4 memory dimm
  • Attributes required: Available memory slot
  • Minimum required: 0
  • Maximum allowed: 4 (Initial order maximum: 4)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#EN0W) - PCIe2 2-port 10/1GbE BaseT RJ45 Adapter

PCIe Gen2 short x8 adapter which provides two 10G-BaseT ports. The ports are RJ45. The ports default to auto negotiate the highest speed either 10Gb (10GBaseT), 1Gb (1000BaseT) or 100Mb (100BaseT) full duplex. Each RJ45 port's configuration is independent of the other. The adapter supports Ethernet NIC (Network Interface Card) traffic.

The RJ45 ports use 4-pair CAT-6A cabling for distances of up to 100 meters or CAT-6 cabling for distances up to 37 meters. CAT5 cabling is not tested and is not supported.

#EN0W and #EN0X are electronically identical with the same CCIN of 2CC4. #EN0W has a full high tail stock and #EN0X has a low profile tail stock.

Details for the ports include:

  • NIM install supported for VIOS, AIX, and Linux
  • IEEE 802.3an (10GBASE-T), IEEE 802.3ab (1000BASE-T GbE), IEEEu (100BASE-T), 802.1p priority, 802.1Q VLAN tagging, 802.3x flow control, 802.3ad load-balancing and failover, Link aggregation, IEEE 802.3ad 802.3
  • Multiple MAC addresses / promiscuous mode (for PowerVM/VIOS) per interface
  • Message Signalling Interrupt (MSI-X, MSI) support of legacy pin interrupts
  • Ether II and IEEE 802.3 encapsulated frames
  • Jumbo frames up to 9.6 Kbytes
  • TCP checksum offload for IPv4 and IPv6
  • TCP segmentation Offload (TSO)
  • RSS (Receive Side Scaling) support for IPv4, IPv6 and UDP
  • UDP checksum offload for IPv4 and IPv6
  • AIX, IBM i, and Linux provide software iSCSI support through the adapter
  • Attributes provided: Two 10G-BaseT ports
  • Attributes required: PCIe Gen2 or Gen3 slot - full high
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#EP75) - 6-core 3.0 GHz POWER9 Processor
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#ERK0) - Fixed Length Rail Kit for 7063-CR2
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#ERK1) - Adjustable Length Rail Kit for 7063-CR2
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required:
  • Initial Order/MES/Both/Supported: Both
  • CSU: Yes
  • Return parts MES: Does not apply
(#ESC0) - S&H - No Charge

No charge shipping and handling

  • Attributes provided: None
  • Attributes required: Sales Preapproval Required
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required: Does not apply
  • Initial Order/MES/Both/Supported: Both
  • CSU: N/A
  • Return parts MES: Does not apply
(#ESC5) - S&H-a

Shipping and handling

  • Attributes provided: None
  • Minimum required: 0
  • Maximum allowed: 1 (Initial order maximum: 1)
  • OS level required: None
  • Initial Order/MES/Both/Supported: Initial
  • CSU: N/A
  • Return parts MES: Does not apply

Feature exchanges

Not applicable.



Back to topBack to top

Accessories

Top rule

Not applicable.

Customer replacement parts

Not applicable.



Back to topBack to top

Supplies

Top rule

Not applicable.

Supplemental media

Not applicable.



Back to topBack to top

Trademarks

Top rule

(R), (TM), * Trademark or registered trademark of International Business Machines Corporation.

** Company, product, or service name may be a trademark or service mark of others.

Terms of use

IBM products and services which are announced and available in your country can be ordered under the applicable standard agreements, terms, conditions, and prices in effect at the time. IBM reserves the right to modify or withdraw this Sales Manual at any time without notice. This Sales Manual is provided for your information only. Additional terms of use are located at

Terms of use


© IBM Corporation 2021.