Use these steps to create an Ethernet line description
on models 8xx so that the system can use virtual Ethernet.
This configuration procedure applies to models 800,
810, 825, 870 and 890.
To configure new Ethernet line descriptions to support virtual Ethernet,
follow these steps:
- On the command line on partition A, type WRKHDWRSC
*CMN and press Enter.
- From the Work with Communication Resources window, select Option
7 (Display resource detail) next to the appropriate virtual Ethernet port.
The Ethernet port identified as 268C is the virtual Ethernet resource.
There is one for each virtual Ethernet that is connected to the logical partition.
- From the Display Resource Detail window, scroll down to find the
port address. The port address corresponds to the virtual Ethernet that you
selected during the configuration of the logical partition.
- From the Work with Communication Resources window, select Option
5 (Work with configuration descriptions) next to the appropriate virtual Ethernet
port, and press Enter.
- From the Work with Configuration Descriptions window, select Option
1 (Create), and then press Enter to see the Create Line Description Ethernet
(CRTLINETH) window.
- At the Line description prompt, type VETH0.
The name VETH0, although arbitrary, corresponds to the numbered column
on the Virtual Ethernet page in which you enabled the logical partitions to
communicate. If you use the same names for the line descriptions and their
associated virtual Ethernet, you can easily keep track of your virtual Ethernet
configurations.
- At the Line speed prompt, type 1G.
- At the Duplex prompt, type *FULL,
and then press Enter.
- At the Maximum frame size prompt, type 8996 and
press Enter.
By changing the frame size to 8996, the transfer
of data across the virtual Ethernet is improved.
You will see a message
stating that the line description has been created.
- Vary on the line description. Type WRKCFGSTS *LIN,
and then select Option 1 (Vary on) for VETH0.
- Repeat steps 1 through 6, but perform the steps from the command
line on partition B to create an Ethernet line description for partition B.
Although the names of the line descriptions are arbitrary, it is
helpful to use the same names for all of the line descriptions associated
with the virtual Ethernet. In this scenario, all the line descriptions are
named VETH0.