Specifying Subfield Length

The length of a subfield may be specified using absolute (positional) or length notation, or its length may be implied.

Absolute
Specify a value in both the From-Position (positions 26 through 32) and the To-Position/Length (positions 33 through 39) entries on the definition specification.
Length
Specify a value in the To-Position/Length (positions 33 through 39) entry. The From-Position entry is blank.
Implied Length
If a subfield appears in the first parameter of one or more OVERLAY keywords, the subfield can be defined without specifying any type or length information. In this case, the type is character and the length is determined by the overlaid subfields.

In addition, some data types, such as Pointers, Dates, Times and Timestamps have a fixed length. For these types, the length is implied, although it can be specified.

When using length notation, the subfield is positioned such that its starting position is greater than the maximum To-Position of all previously defined subfields. For examples of each notation, see Data Structure Examples.