Including disk units in a parity set

Start of changeWhen you attach a new disk unit to an existing IOA that has device parity protection, you can include the disk unit into an existing parity set with other disk units.End of change

Attention: Start of changeIncluding disk units into an existing parity set with PCIe2, PCIe3, and newer generations of SAS RAID adapters can result in a large performance degradation. The degradation can occur because the adapter uses firmware in place of specialized hardware assists when drives are included into an existing parity set. For this reason, the Include disk operation is no longer recommended with PCIe2, PCIe3, and newer generations of SAS RAID adapters. Systems with POWER8® technology and beyond do not allow the Include disk operation. Alternatives for adding disk units to the system are to stop parity on the existing set and then start parity with the additional disks in the set, or to create a new parity set of three or more disks with the additional disk units.End of change

Start of changeIf you want to include a disk unit in a parity set and the disk units of that parity set are in an independent disk pool, the independent disk pool must be varied off. For all other disk pools, you must restart your system to dedicated service tools (DST) mode before you can include them in a parity set.End of change

Adding three or more disk units requires you to create a new parity set. The include function does not work when creating a parity set. To create a parity set, go to Start device parity protection.

For a Small Computer System Interface (SCSI) IOA, the disk units being included must be the same capacity as the other disk units in the parity set. For a Serial Attached SCSI (SAS) IOA, the disk units being included can be the same capacity or larger than the other disk units in the parity set

To include a disk unit in a parity set, follow these steps:

  1. Select Configuration and Service from your IBM® Systems Director Navigator for i5/OS window.
  2. Select Disk Units.
  3. Select the disk unit that you want to include.
  4. From the Select Actions menu, select Include in Parity Set.

To include a disk unit in a parity set, follow these steps:

  1. In System i® Navigator, expand My Connections (or your active environment).
  2. Expand the System i you want to examine,Configuration and Service > Hardware > Disk Units.
  3. Select the disk units that you want to include.
  4. Right-click a selected disk unit and select Include in Parity Set.
  5. From the resulting dialog box, click Include to include the selected disk units in a parity set.