Create Ctl Desc (Retail) (CRTCTLRTL)

Where allowed to run: All environments (*ALL)
Threadsafe: No
Parameters
Examples
Error messages

The Create Controller Description (Retail) (CRTCTLRTL) command creates a controller description for a retail controller.

Restriction: You must have input/output system configuration (*IOSYSCFG) special authority to use this command.

Top

Parameters

Keyword Description Choices Notes
CTLD Controller description Name Required, Positional 1
TYPE Controller type 3651, 3684, 4680, 4684 Required, Positional 2
MODEL Controller model 0 Required, Positional 3
LINKTYPE Link type *SDLC, *X25, *LAN Required, Positional 4
ONLINE Online at IPL *YES, *NO Optional
SWITCHED Switched connection *NO, *YES Optional
SNBU Switched network backup *NO, *YES Optional
LINE Attached nonswitched line Name Optional
SWTLINLST Switched line list Values (up to 64 repetitions): Name Optional
MAXFRAME Maximum frame size 265-1994, 256, 265, 512, 521, 1024, 1033, 1994, *LINKTYPE Optional
EXCHID Exchange identifier 00100000-FFFFFFFF Optional
INLCNN Initial connection *DIAL, *ANS Optional
CNNNBR Connection number Character value, *ANY Optional
ANSNBR Answer number *CNNNBR, *ANY Optional
STNADR Station address 01-FE Optional
ADPTADR LAN remote adapter address 000000000001-FFFFFFFFFFFF Optional
DSAP LAN DSAP 04, 08, 0C, 10, 14, 18, 1C, 20, 24, 28, 2C, 30, 34, 38, 3C, 40, 44, 48, 4C, 50, 54, 58, 5C, 60, 64, 68, 6C, 70, 74, 78, 7C, 80, 84, 88, 8C, 90, 94, 98, 9C Optional
SSAP LAN SSAP 04, 08, 0C, 10, 14, 18, 1C, 20, 24, 28, 2C, 30, 34, 38, 3C, 40, 44, 48, 4C, 50, 54, 58, 5C, 60, 64, 68, 6C, 70, 74, 78, 7C, 80, 84, 88, 8C, 90, 94, 98, 9C Optional
NETLVL X.25 network level 1980, 1984, 1988 Optional
LGLCHLID X.25 logical channel ID Character value Optional
CNNPWD X.25 connection password Character value, X'' Optional
TEXT Text 'description' Character value, *BLANK Optional
DEV Attached devices Values (up to 254 repetitions): Name Optional
CODE Character code *EBCDIC, *ASCII Optional
SSCPID SSCP identifier 000000000001-FFFFFFFFFFFF, 050000000000 Optional
PREDIALDLY Predial delay 0-254, 6 Optional
REDIALDLY Redial delay 0-254, 120 Optional
DIALRTY Dial retry 0-254, 2 Optional
SWTDSC Switched disconnect *YES, *NO Optional
POLLPTY SDLC poll priority *NO, *YES Optional
POLLLMT SDLC poll limit 0-4, 0 Optional
OUTLMT SDLC out limit *POLLLMT, 0, 1, 2, 3, 4 Optional
CNNPOLLRTY SDLC connect poll retry 0-65534, *CALC, *NOMAX Optional
NDMPOLLTMR SDLC NDM poll timer 0-3000, *CALC Optional
LANFRMRTY LAN frame retry 0-254, *CALC Optional
LANCNNRTY LAN connection retry 0-254, *CALC Optional
LANRSPTMR LAN response timer 0-254, *CALC Optional
LANCNNTMR LAN connection timer 0-254, *CALC Optional
LANACKTMR LAN acknowledgement timer 0-254, *CALC Optional
LANINACTMR LAN inactivity timer 0-255, *CALC Optional
LANACKFRQ LAN acknowledgement frequency 0-127, *CALC Optional
LANMAXOUT LAN max outstanding frames 1-127, *CALC Optional
LANACCPTY LAN access priority 0-3, *CALC Optional
LANWDWSTP LAN window step 1-127, *NONE Optional
SWTLINSLCT X.25 switched line selection *FIRST, *CALC Optional
DFTPKTSIZE X.25 default packet size Element list Optional
Element 1: Transmit value *LIND, 64, 128, 256, 512, 1024, 2048, 4096
Element 2: Receive value *LIND, *TRANSMIT, 64, 128, 256, 512, 1024, 2048, 4096
DFTWDWSIZE X.25 default window size Element list Optional
Element 1: Transmit value 1-15, *LIND
Element 2: Receive value 1-15, *LIND, *TRANSMIT
USRGRPID X.25 user group identifier Character value Optional
RVSCRG X.25 reverse charging *NONE, *REQUEST, *ACCEPT, *BOTH Optional
X25FRMRTY X.25 frame retry 0-21, 7 Optional
X25CNNRTY X.25 connection retry 0-21, 7 Optional
X25RSPTMR X.25 response timer 1-2550, 100 Optional
X25CNNTMR X.25 connection timer 1-2550, 100 Optional
X25DLYTMR X.25 delayed connection timer 1-32767, *CALC Optional
USRFCL User facilities Character value Optional
CMNRCYLMT Recovery limits Single values: *SYSVAL
Other values: Element list
Optional
Element 1: Count limit 0-99, 2
Element 2: Time interval 0-120, 5
AUT Authority Name, *CHANGE, *ALL, *USE, *EXCLUDE, *LIBCRTAUT Optional
Top

Controller description (CTLD)

This is a required parameter.

Specifies the name of the controller description.

Top

Controller type (TYPE)

This is a required parameter.

Specifies the type of controller for this description.

3651

This description represents a 3651 controller.

3684

This description represents a 3684 controller.

4680

This description represents a 4680 controller.

4684

This description represents a 4684 controller.

Note: For a 4690, specify 4680 for the controller type.

Top

Controller model (MODEL)

This is a required parameter.

Specifies the model number of the controller that is described. This number tells the system which features the controller has.

Top

Link type (LINKTYPE)

Specifies the type of line to which this controller is attached.

This is a required parameter.

*SDLC

This controller is attached to a synchronous data link control (SDLC) line.

*X25

This controller is attached to an X.25 line.

*LAN

This controller is attached to a distributed data interface (DDI), Ethernet, or token-ring local area network line.

Top

Online at IPL (ONLINE)

Specifies whether this object is automatically varied on at initial program load (IPL).

*YES

The controller is automatically varied on at IPL.

*NO

The controller is not automatically varied on at IPL.

Top

Switched connection (SWITCHED)

Specifies whether this controller is attached to a switched line, a token-ring network, Ethernet LAN, or an X.25 switched virtual circuit (SVC). *NO must be specified for APPC controllers attached to a TDLC line.

*NO

This controller is attached to a nonswitched line. Specify this value for controllers attaching to an X.25 permanent virtual circuit (PVC).

*YES

This controller is attached to a switched line. Specify this value for controllers attached to an X.25 switched virtual circuit (SVC). Also specify this value for controllers attached to a local area network.

Note: If LINKTYPE is *LAN, the SWITCHED parameter value must be *YES or must not be specified.

Top

Switched network backup (SNBU)

Specifies whether the remote system modem has the switched network backup (SNBU) feature. The backup feature is used to bypass a broken nonswitched (leased line) connection by establishing a switched connection. To activate SNBU, you must change the controller description of the modem from nonswitched to switched by specifying *YES for the Activate swt network backup (ACTSNBU) parameter.

Note: If the modem model you are using is an IBM 386x, 586x, or 786x, you should not change the controller description. Instead, manually switch the modem to the unswitched mode, and manually dial the connection.

Both the local and remote modems must support the SNBU feature to perform a valid activation.

*NO
The remote system modem does not have the SNBU feature.
*YES

The remote system modem has the SNBU feature.

Top

Attached nonswitched line (LINE)

Specifies the name of the nonswitched line to which this controller is attached. The line description must already exist.

Note: The associated line must be varied off before this command is entered. Specify this parameter for controllers attaching to an X.25 permanent virtual circuit (PVC).

Top

Switched line list (SWTLINLST)

Specifies the names of the switched lines to which this controller attaches. The line descriptions must already exist. Up to 64 switched line names can be specified.

switched-line-name

Specify the names of up to 64 lines that are connected to this controller. The same line name can be used more than once. For each line name specified, a line description by that name must already exist.

Top

Maximum frame size (MAXFRAME)

Specifies the maximum frame (path information unit (PIU)) size the controller can send or receive. This value is used to calculate the request unit (RU) sizes. Since the maximum PIU size that the controller can send or receive is negotiated at exchange identifier time, the maximum PIU size used at run time may be different. This value matches the corresponding value on the host system.

*LINKTYPE

The frame size is 521 bytes for *SDLC, 1024 bytes for *X25, and 1994 bytes for *LAN.

maximum-frame-size

Specify either 521, 1033, or 1994 bytes as the maximum frame size for this controller. Specify 1024 only if linktype is *X25. Specify 1994 only if linktype is *LAN.

Top

Exchange identifier (EXCHID)

Specifies the exchange identifier of this controller. The controller sends (exchanges) its identifier to another location when a connection is established. The 8-digit hexadecimal identifier contains 3 digits for the block number and 5 digits for the identifier of the specific controller.

                  Block       Hexadecimal
Controller        Number      Identifier
3694              02F         xxxxx
4701              057         xxxxx
4702              057         xxxxx
4730              043         xxxxx
4731              043         xxxxx
4732              043         xxxxx
4736              043         xxxxx
*FBSS             000-FFF     xxxxx
3601 (configured  016         xxxxx
      as a 4701)

Top

Initial connection (INLCNN)

Specifies the method used to establish a connection with this controller.

*DIAL

The system initiates outgoing calls and answers incoming calls.

*ANS

The connection is made by the IBM System i5 when it answers an incoming call from this controller. If a call is received from the remote controller and all necessary conditions are met, the incoming call is answered by the system.

For X.25 connections, the line attached to the controller requires switched virtual circuits (SVCs) configured on the LGLCHLE parameter of type OUT or BOTH(*SVCOUT or *SVCBOTH) for the connection to succeed.

The line can be changed using the Change Line Description (X.25) (CHGLINX25) command.

Top

Connection number (CNNNBR)

Specifies the telephone number to dial to connect to this controller.

*ANY
The system accepts calls from any network address.
Top

Answer number (ANSNBR)

Specifies the X.25 network address from which calls are accepted.

*CNNNBR

Calls from the X.25 network address specified on the CNNNBR parameter are accepted.

*ANY

Calls are accepted from any X.25 network address.

Top

Station address (STNADR)

Specifies the station address used when communicating with the controller.

Valid values range from 00 to FE.

Note: 00 can be specified only for APPC controllers when *TDLC is specified for the Link type (LINKTYPE) parameter.

Note: If *SEC is specified on the ROLE parameter, this is the station address of the remote controller. If *PRI or *NEG is specified on the ROLE parameter, this is the local station address.

Top

LAN remote adapter address (ADPTADR)

Specifies the 12-character adapter address of the remote controller. This is the address to which the system sends data when it communicates with the remote controller. This value can be obtained from the remote controller's configuration record. Valid values range from hex 000000000001 through hex FFFFFFFFFFFF.

adapter-address

Specify the adapter address of the remote controller.

Top

LAN DSAP (DSAP)

Specifies the destination service access point (DSAP). This is the logical address this system will send to when it communicates with the remote controller. This address allows the controller to properly route the data that comes from this system. The default value for the destination service access point is 04.

The value must match the value specified on the source service access point (SSAP) parameter in the remote controller's configuration record.

04

The destination service access point is the default 04.

destination-service-access-point

Specify a hexadecimal value ranging from 04 through 9C, in increments of 4 (for example, 04, 08, 0C, 10) to represent the destination service access point.

Top

LAN SSAP (SSAP)

Specifies the source service access point (SSAP). This is the logical address the local system uses when it sends data to the remote controller. This address allows the controller to properly route the data that comes from the local system. The default value for the source service access point is 04.

It must match the value assigned to the destination service access point (DSAP) in the remote controller's configuration record.

04

The system uses the logical address of 04.

source-service-access-point

Specify a hexadecimal value ranging from 04 through 9C, in increments of 4 (for example, 04, 08, 0C, 10) to represent the source service access point.

Top

X.25 network level (NETLVL)

Specifies the level of the X.25 network used to access this controller. The level is specified by giving the year of the standard used by the X.25 network.

Note: Use of the lower value of the remote DTE or the network level is suggested; for example, if the remote DTE is using the CCITT standard of 1980 and the network 1984, specify 1980 for this parameter.

1980

The 1980 Standard is used.

1984

The 1984 Standard is used.

1988

The 1988 Standard is used.

Top

X.25 logical channel ID (LGLCHLID)

Specifies the logical channel identifier used for the X.25 permanent virtual circuit (PVC) to this controller. The valid entry is xyy. Where:

Top

X.25 connection password (CNNPWD)

Specifies the X.25 network password used for password exchange with the X.24 Call Request and Incoming Call packets (Call User Data field). This parameter is not valid for permanent virtual circuit (PVC) connections.

If you want to use a connection password that consists of characters whose hexadecimal value is less than 40, you must specify the password as a hexadecimal value. When less than 8 bytes are specified, the end of the password field is padded with blanks. A password of all blank is valid. All incoming call requests must match this password to establish a connection.

To specify a hexadecimal password, the digits must be specified in multiples of two, be no more than 16 digits long, be enclosed in apostrophes, and be preceded by an X. For example, X'0102030405' is a valid hexadecimal password.

Note: This connection password is highly recommended for controllers that operate with the Enhanced Logical Link Control (ELLC) protocol LINKPCL(*ELLC) on switched virtual circuit (SVC) connections. This enhanced protocol supports reconnection of virtual circuits after network errors which disconnect the line with a clear signal; however, this reconnection is not allowed to proceed without the password validation procedure being used as a unique identifier for the controller.

X.25-connection-password

Specify the connection password. The password for each controller can consist of any alphanumeric characters represented by the hexadecimal values ranging from 40 through FF.

Top

Text 'description' (TEXT)

Specifies the text that briefly describes the object.

*BLANK

No text is specified.

character-value

Specify no more than 50 characters of text, enclosed in apostrophes.

Top

Attached devices (DEV)

Specifies the names of the devices that are attached to this controller. The device descriptions must already exist.

The maximum number of devices that can attach to this controller is 14 for a 3651 controller, 2 for a 3684 controller, 84 for a 4680 controller, and 254 for a 4684 controller.

The maximum number of devices that can be active is 14 for a 3651 controller, 2 for a 3684 controller, 40 for a 4680 controller, and 16 for a 4684 controller.

Top

Character code (CODE)

Specifies whether the extended binary-coded decimal interchange code (*EBCDIC) or the American National Standard Code for Information Interchange (*ASCII) character code is used on the line.

*EBCDIC

The extended binary-coded decimal interchange code (EBCDIC) character code is used.

*ASCII
The ASCII character code is used.
Top

SSCP identifier (SSCPID)

Specifies the system service control point identifier of the host system.

050000000000

The default value for the system service control point identifier.

system-service-control-point-identifier

Specify the system service control point identifier as a 12-digit hexadecimal value.

Top

Predial delay (PREDIALDLY)

Specifies the time interval to wait (in 0.5 second intervals) before dialing a number.

6

The default value of 6 provides a 3-second delay.

predial-delay
Specify a value ranging from 0 to 254 units. Each unit represents 0.5 second. To indicate no delay, specify a value of 0.
Top

Redial delay (REDIALDLY)

Specifies the time interval to wait (in 0.5 second intervals) before re-dialing when the call attempt is unsuccessful.

120
The default value of 120 provides a 60-second delay.
redial-delay
Specify a value from 0 to 254 units. Each unit represents 0.5 second. To indicate no delay, specify a value of 0.
Top

Dial retry (DIALRTY)

Specifies the number of re-dial attempts made by the system before considering the dialing unsuccessful.

2
The default number of retries is 2.
dial-retry
Specify a value from 0 to 254 in 0.5-second intervals, for the number of times the dialing will be tried.
Top

Switched disconnect (SWTDSC)

Specifies whether the switched connection to this controller is dropped when the last device is varied off.

*NO

The switched connection is not dropped when the last device is varied off.

*YES

The switched connection is varied off when the last device is varied off.

Top

SDLC poll priority (POLLPTY)

Specifies whether this controller has priority when polled. This parameter can be specified only if SHM is *NO.

*NO

This controller does not have polling priority.

*YES

This controller does have polling priority.

Top

SDLC poll limit (POLLLMT)

Specifies, for an SDLC secondary or negotiable controller, the number of consecutive polls issued to the same controller when the poll results in receiving frames. This parameter can be specified only if SHM is *NO.

0

The default number of polls is zero.

poll limit

Specify a number of polls. Valid values range from 0 through 4.

Top

SDLC out limit (OUTLMT)

Specifies the number of consecutive times SDLC allows the transmission of the maximum number of frames to a station, before allowing transmission to another station.

*POLLLMT

The value is the same as the one specified for the SDLC poll limit (POLLLMT) parameter.

out-limit

Specify a value ranging from 0 through 4.

Top

SDLC connect poll retry (CNNPOLLRTY)

Specifies the number of times to retry connecting to a controller before reporting an error.

*CALC

The number of retries is 7 if the controller is switched, and *NOMAX if the controller is nonswitched.

*NOMAX

The system will retry indefinitely.

connect-poll-retry

Specify a value ranging from 0 to 65534 for the number of retries.

Top

SDLC NDM poll timer (NDMPOLLTMR)

Specifies the minimum interval at which a secondary station should be polled if a poll from the primary to the secondary (which is in normal disconnect mode (NDM)) does not result in receiving the appropriate response.

This parameter is valid only if the link type is *SDLC and the controller role is secondary or negotiable and *NO is specified on the SHM parameter.

*CALC

The poll interval is calculated by the system.

NDM-poll-timer

Specify a value ranging from 1 to 3000 units. Each unit represents 0.1 second. To indicate no timer, specify 0.

Top

LAN frame retry (LANFRMRTY)

Specifies the number of times to retry a transmission when there is no acknowledgment from the remote controller in the time period specified by the LANRSPTMR parameter. This value is only used after a successful connection has been made.

*CALC

The system determines the timer value.

LAN-frame-retry

Specify a value ranging from 0 through 254 for the number of times a frame is transmitted before an acknowledgement is received.

Top

LAN connection retry (LANCNNRTY)

Specifies the number of times a transmission is attempted before an acknowledgement is received. This value is used at connection time (unlike LANFRMRTY which is used after a connection has been made).

*CALC

The system determines the timer value.

LAN-connection-retry

Specify a value ranging from 0 through 254 for the number of times the transmission is attempted before an acknowledgement is received.

Top

LAN response timer (LANRSPTMR)

Specifies the time period used to determine an inoperative condition on the link when connected.

*CALC

The system determines the timer value.

LAN-response-timer

Specify a value from 1 to 254 units. Each unit represents 0.1 second. To indicate no timer, specify 0.

Top

LAN connection timer (LANCNNTMR)

Specifies the time period used to determine an inoperative condition on the link at connection time.

*CALC

The system determines the timer value.

LAN-connection-timer

Specify a value ranging from 1 through 254 in 0.1-second intervals for the amount of time the system waits before an inoperative condition occurs. To indicate no timer, specify 0.

Top

LAN acknowledgement timer (LANACKTMR)

Specifies the time interval to delay sending acknowledgements for received frames.

*CALC

The system determines the timer value.

LAN-acknowledgement-timer

Specify a value ranging from 1 to 254 units. Each unit represents 0.1 second. To indicate no timer, specify 0. If 0 is specified for the LAN acknowledgement frequency (LANACKFRQ) parameter, 0 must also be specified for this parameter. If a non-zero number is specified for the LANACKFRQ parameter, a non-zero number must also be specified for this parameter.

Top

LAN inactivity timer (LANINACTMR)

Specifies the time period used to determine an inactive condition for the controller.

*CALC

The system determines the timer value.

LAN-inactivity-timer

Specify a value ranging from 1 through 255 in 0.1-second intervals for the length of time used to determine an inactive condition for the controller. To indicate no timer, specify 0.

Top

LAN acknowledgement frequency (LANACKFRQ)

Specifies the maximum number of frames received before sending an acknowledgement to the controller.

*CALC

The system determines the LAN acknowledgement frequency value.

LAN-acknowledge-frequency

Specify a value from 0 to 127 for the number of frames received. If 0 is specified for the LAN acknowledgement timer (LANACKTMR) parameter, 0 must also be specified for this parameter. If a non-zero number is specified for the LANACKTMR parameter, a non-zero number must also be specified for this parameter.

Top

LAN max outstanding frames (LANMAXOUT)

Specifies the maximum number of frames that can be sent before an acknowledgement is received from the remote system.

*CALC

The system determines the LAN maximum outstanding frames value.

LAN-maximum-outstanding-frames

Specify a value ranging from 1 through 127 for the number of frames that can be sent before an acknowledgement is received.

Top

LAN access priority (LANACCPTY)

Specifies the priority granted to the sending system for sending frames. The larger the number, the higher the priority.

*CALC
The system calculates the value to use.
LAN-access-priority

Specify a value from 0 to 3 for the access priority for this controller on a local area network (LAN).

Top

LAN window step (LANWDWSTP)

Specifies whether to reduce to 1 the maximum number of frames outstanding to the remote system during network congestion. This parameter (LAN Window Step) indicates the number of frames that must be successfully received by the remote system before the number of maximum outstanding frames can be increased by 1. The increase continues this way until the maximum number of outstanding frames reaches the value specified by the LAN maximum outstanding frames (LANMAXOUT) parameter.

*NONE

The number of outstanding frames is not reduced during network congestion.

LAN-window-step

Specify a value from 1 to 127 for the number of frames that must be successfully received by the remote system before the maximum number of outstanding frames can be increased by 1.

Top

X.25 switched line selection (SWTLINSLCT)

Specifies the method that is used to select lines from an X.25 switched line list.

*FIRST

Lines are selected beginning with the first line in the switched line list.

*CALC

The system determines which line in the switched line list will be selected.

Top

X.25 default packet size (DFTPKTSIZE)

Specifies the default packet size used by the X.25 network for transmission and reception.

Element 1: Transmit Packet Size

*LIND

The value specified in the line description is the default value.

transmit-packet-size

Specify a default packet size for transmission. The valid values for the packet size are 64, 128, 256, 512, 1024, 2048, and 4096.

Element 2: Receive Packet Size

*LIND

The value specified in the line description is the default value.

*TRANSMIT

The value specified as the default packet size for transmission is used as the default for reception.

receive-packet-size

Specify a default packet size for reception. The valid values for the packet size are 64, 128, 256, 512, 1024, 2048, and 4096.

Top

X.25 default window size (DFTWDWSIZE)

Specifies the default window size for transmission and reception.

Element 1: Transmit Window Size

*LIND

The value specified in the line description is used as the default window size.

transmit-window-size

Specify the appropriate default window size. If you specified modulus 8, valid values range from 1 through 7. If you specified modulus 128, valid values range from 1 through 15. For switched virtual circuit (SVC) incoming calls, the system accepts the window size indicated in the Incoming Call packet facilities field.

Element 2: Receive Window Size

*LIND

The value specified in the line description is used as the default window size.

*TRANSMIT

The value specified as the default window size for transmission is used as the default for reception.

receive-window-size

Specify the appropriate default window size. If you specified modulus 8, valid values range from 1 through 7. If you specified modulus 128, valid values range from 1 through 15.

Top

X.25 user group identifier (USRGRPID)

Specifies the closed user-group ID for contacting this switched virtual circuit (SVC) controller on the X.25 network.

Specify the 2-digit decimal value, from 00 through 99, as provided by the network subscription. This parameter is not valid for permanent virtual circuit (PVC) connections. It is valid only for SVC circuit outgoing call operations and is ignored for SVC incoming call connections.

Top

X.25 reverse charging (RVSCRG)

Specifies whether reverse charges are accepted or requested when contacting this controller.

*NONE

No reverse charging for network tariff billing is accepted.

*REQUEST

Charges are requested on outgoing call request packets.

*ACCEPT

Reverse charging for network tariff billing is accepted on incoming requests.

*BOTH

Both incoming and outgoing requests are accepted.

Top

X.25 frame retry (X25FRMRTY)

Specifies the maximum number of times a frame is sent after the response timer ends when connected to this controller. The value for this parameter depends on the quality of service provided by the network and the connection to that network; that is, the frequency of lost link protocol data units.

7

The default for the maximum number of transmissions is 7.

X.25 frame retry

Specify a value ranging from 0 through 21 for the number of times a frame is sent.

Top

X.25 connection retry (X25CNNRTY)

Specifies the maximum number of times that a logical link control (LLC) protocol data unit is sent after the connect response timer expires when connecting to this controller.

7

The default for the maximum number of transmissions is 7.

X.25 connection retry

Specify a value ranging from 0 through 21 for the number times a frame is sent.

Top

X.25 response timer (X25RSPTMR)

Specifies the time period allowed to return an acknowledgement when an LLC protocol data unit is sent while connected to this controller.

100

The default amount of time is 10 seconds.

X.25 response-timer

Specify an amount of time in tenths of a second. Valid values range from 1 through 2550 in 0.1-second intervals.

Top

X.25 connection timer (X25CNNTMR)

Specifies the time period allowed to return an acknowledgement when an LLC protocol data unit is sent while connecting to this controller.

100

The default amount of time is 10 seconds.

connection-timer

Specify an amount of time in tenths of a second. Valid values range from 1 through 2550 in 0.1 second intervals.

Top

X.25 delayed connection timer (X25DLYTMR)

Specifies the time interval between attempts to establish a connection to the controller.

*CALC

Use the values specified for the X.25 connection timer (X25CNNTMR) parameter and the X.25 connection retry (X25CNNRTY) parameter to determine how often and how many times to try establishing the connection.

X.25-delay-timer

Specify a value ranging from 1 to 32767 units. Each unit represents 0.1 second. Connection attempts are repeated indefinitely at this time interval.

Top

User facilities (USRFCL)

Specifies a string of hexadecimal characters sent to the X.25 network to request additional services. The system allows up to 218 hexadecimal characters.

Top

Recovery limits (CMNRCYLMT)

Specifies the number of recovery attempts made by the system before an inquiry message is sent to the system operator. Also specifies the time (in minutes) that must elapse before the system sends an inquiry message to the system operator indicating that the recovery attempt count limit is reached.

Element 1: Maximum Recovery Limit

2

Two recovery attempts are made within the interval specified.

*SYSVAL
The value in the QCMNRCYLMT system value is used.
count limit

Specify the number of second-level recovery attempts to be made. Valid values range from 0 through 99.

Element 2: Recovery Time Interval

5

The specified number of recovery attempts is made within a 5-minute interval.

time-interval

Specify the time interval (in minutes) at which the specified number of second-level recoveries are attempted. Valid values range from 0 through 120. If the value specified for count-limit is not 0, the value 0 specifies infinite recovery.

More information on communication recovery is in the Communcations Management book, SC41-5406.

Top

Authority (AUT)

Specifies the authority you are giving to users who do not have specific authority for the object, who are not on an authorization list, and whose group profile or supplemental group profiles do not have specific authority for the object.

*CHANGE
The user can perform all operations on the object except those limited to the owner or controlled by object existence (*OBJEXIST) and object management (*OBJMGT) authorities. The user can change and perform basic functions on the object. *CHANGE authority provides object operational (*OBJOPR) authority and all data authority. If the object is an authorization list, the user cannot add, change, or remove users.
*ALL
The user can perform all operations except those limited to the owner or controlled by authorization list management (*AUTLMGT) authority. The user can control the object's existence, specify the security for the object, change the object, and perform basic functions on the object. The user also can change ownership of the object.
*USE
The user can perform basic operations on the object, such as running a program or reading a file. The user cannot change the object. Use (*USE) authority provides object operational (*OBJOPR), read (*READ), and execute (*EXECUTE) authorities.
*EXCLUDE
The user cannot access the object.
*LIBCRTAUT
The system determines the authority for the object by using the value specified for the Create authority (CRTAUT) parameter on the Create Library (CRTLIB) command for the library containing the object to be created. If the value specified for the CRTAUT parameter is changed, the new value will not affect any existing objects.
name
Specify the name of an authorization list to be used for authority to the object. Users included in the authorization list are granted authority to the object as specified in the list. The authorization list must exist when the object is created.
Top

Examples

CRTCTLRTL   CTLD(CTLR05)  TYPE(3651)  MODEL(0)  LINKTYPE(*SDLC)
            SWITCHED(*YES)  SWTLINLST(SWITCHED1)
            EXCHID(00500005)
            INLCNN(*ANS)  STNADR(E1)  CNNNBR(2553217)

This command creates a 3651 Model 0 retail controller description called CTLR05. The controller is on a SDLC switched line at telephone number 255-3217. Connection to the controller is initiated by an incoming call to the IBM System i.

Top

Error messages

*ESCAPE Messages

CPF26BB
Extended wireless controller member not changed.
CPF26BC
Extended wireless controller member not displayed.
CPF26BD
Entry for barcode group not removed from extended wireless controller member.
CPF26BE
Entry for PTC group not removed from extended wireless controller member.
CPF26BF
Program QZXCINZ terminated abnormally. See previous messages.
CPF26B3
Extended wireless line member not added.
CPF26B4
Extended wireless line member not changed.
CPF26B5
Extended wireless line member not displayed.
CPF26B8
Extended wireless controller member not added.
CPF2716
Controller description &1 not created.
Top