Enrolling Tape Automation Media (volume) into BRMS

From the Work with Media Libraries display (WRKMLMBRM) command, select option 1 (Add MLB media) against the media library device that is attached to your system. This takes you to the ADDMLMBRM prompt display as shown below.

                      Add MLB Media using BRM (ADDMLMBRM)
                                                                                    
  Type choices, press Enter.                                                        
                                                                                    
  Media library device . . . . . . > MLB01   Name                                   
  Volume identifier  . . . . . . .   *INSERT       Character value, *INSERT         
                 + for more values                                                  
  Add volume to BRM  . . . . . . . > *YES          *NO, *YES                        
  Initialize tape  . . . . . . . .   *NO           *NO, *YES                        
  Media class  . . . . . . . . . . > CART3490E     CART3490E, QIC120...             
  Last moved date  . . . . . . . .   *NONE         Date, *NONE                      
  Move policy  . . . . . . . . . .   *NONE         *NONE, OFFSITE                   
                                                                                    

You can enroll all newly-inserted volumes into the BRMS media inventory. If you use the default value for the VOL parameter (*INSERT) and change the Add volume to BRM field to *YES, all volumes that were previously in the *INSERT category (from the Work with MLB Media display) are enrolled into the BRMS media inventory and are available for use.