Exempting Volumes from Movement

Occasionally there are times where you might require a volume to be brought back on site for restore purposes or for many other reasons. However, once that volume is brought back on site, and movement has been ran, the volume moves back to the location directed by the move policy associated with it. This feature allows you to exempt the volume from the move policy for a specified amount of time. To exempt a media from movement, take the following steps:

  1. Type WRKMEDBRM at a command line and press Enter.
  2. Type an 8 (Move) in front of the volume you want to move.
  3. The Move Media display allows you to change the Storage Location, Container and also provide a number of days to exempt the volume from movement.
                                       Move Media                                   
                                                                                    
     Type storage location or container to receive volumes.                         
                                                                                    
       Storage location . .   *SAME        *SAME, F4 for list                       
       Container  . . . . .   *SAME        *SAME, F4 for list                       
       Exempt from movement   *SAME        *SAME, 0 - 9999                          
                                                                                    
         Volume          Creation Expiration            Move     Media      Dup     
     Opt Serial   Status   Date      Date    Location   Date     Class      Sts     
     8   LN4072    *ACT  05/01/07  06/05/07  NET3590    *NONE    FMT3590H           
                                                                                    
                                                                                    
                                                                                    
                                                                                    
                                                                                    
                                                                                    
                                                                                    
                                                                                    
                                                                                    
                                                                                    
                                                                             Bottom 
     F12=Cancel                                                                     
  4. After you review and change the parameters, press Enter.


[ Top of Page | Previous Page | Next Page | Contents | Index ]