Write Structured Field Minor (QsnWrtSFMin) API


  Required Parameter Group:

1 Minor structure Input Char(*)
2 Minor structure length Input Binary(4)
3 Command buffer handle Input Binary(4)

  Omissible Parameter Group:

4 Low-level environment handle Input Binary(4)
5 Error code I/O Char(*)

  Returned Value:

Return code Output Binary(4)

  Default Public Authority: *USE

  Service Program: QSNAPI

  Threadsafe: No

The Write Structured Field Minor (QsnWrtSFMin) API writes the minor structure of a structured field, incrementing the length field in the corresponding major structure by the length of this minor structure. The QsnWrtSFMin API must directly follow a QsnWrtSFMaj or QsnWrtSFMin operation to the given command buffer.

Use this API in conjunction with the Write Structured Field Major (QsnWrtSFMaj) API to construct a structured field operation. For indirect operations, the length contained in the minor structure data parameter is added to the stored length for this major structure for every indirect QsnWrtSFMin operation encountered directly after this operation. In this way, you need only calculate the length of each individual structure for constructing a structured field operation. See the 5494 Remote Control Unit Functions Reference, SC30-3533, for more information regarding structured fields.


Authorities and Locks

None.


Restrictions

Not all structured field types are supported by all devices. A negative response code is issued if an attempt is made to write a type to a device that does not support it.


Required Parameter Group

Minor structure
INPUT; CHAR(*)

The minor structure to be written to the screen. The data must consist of the entire minor structure as documented in the 5494 Remote Control Unit Functions Reference, SC30-3533.

Minor structure length
INPUT; BINARY(4)

The length of the minor structure.

Command buffer handle
INPUT; BINARY(4)

A handle for the command buffer in which to store the command. The last operation stored in this command buffer must have been either a QsnWrtSFMaj or QsnWrtSFMin operation.


Omissible Parameter Group

Low-level environment handle
INPUT; BINARY(4)

The low-level environment that the operation applies to. If this parameter is omitted or given with a value of zero, the default low-level environment is used.

Error code
I/O; CHAR(*)

The structure in which to return error information. For the format of the structure, see Error code parameter. If this parameter is omitted, diagnostic and escape messages are issued to the application.


Returned Value

Return code
OUTPUT; BINARY(4)

A return code indicating the result of the operation. The value returned will be 0 if the operation was successful, or -1 otherwise.


Error Messages

Message ID Error Message Text
CPF24B4 E Severe error while addressing parameter list.
CPF3CF1 E Error code parameter not valid.
CPF3CF2 E Error(s) occurred during running of &1 API.
CPFA301 E Command buffer is full.
CPFA303 E Error occurred for screen I/O operation.
CPFA304 E Data-stream error &1 reported for screen I/O operation.
CPFA305 E Cannot add operation to command buffer.
CPFA307 E Screen position &1, &2 outside of display or window area.
CPFA308 E Attempt to write data past end of display.
CPFA30D E Invalid screen attribute.
CPFA31D E Attempt to write outside of window area.
CPFA31E E Required parameter &1 omitted.
CPFA331 E Buffer handle incorrect.
CPFA333 E Parameter &1 not positive integer value.
CPFA334 E Low level environment handle incorrect.
CPFA335 E Screen address parameter error.
CPFA33B E Incorrect operation before QsnWrtSFMin.
CPFA33C E Undefined field ID &1.
CPFA341 E Length &2 of structure incorrect.
CPFA343 E Output operation not done.
CPFA344 E The file &2 in library &3 is not valid.
CPFA345 E The invite active flag is not valid.


API introduced: V2R3