Using DASD devices for multi-volume dump
You can handle large dumps, up to the combined size of 32 DASD partitions, by creating dumps across multiple volumes.
Before you begin
About this task
You can specify up to 32 partitions on ECKD DASD volumes for a multi-volume dump. The dump tool is installed on each volume involved. The volumes must be formatted with the compatible disk layout (cdl, the default option when using the dasdfmt command.)
You must specify block size 4096 for dasdfmt.
For example, Figure 1 shows three DASD volumes,
dasdb, dasdc, and dasdd, with four
partitions selected to contain the dump. To earmark the partition for dump, a dump signature is
written to each partition.
The partitions need to be listed in a configuration file, for example:
/dev/dasdb2
/dev/dasdc1
/dev/dasdd1
/dev/dasdd3
You can define a maximum of three partitions on one DASD. All three volumes are
prepared for IPL; regardless of which you use the result is the same.The following sections will take you through the entire process of creating a multi-volume dump.