Communities widget error messages
Use the codes included in the error messages generated by IBM® Connections to identify problems with Communities widgets and find solutions.
The following error messages are generated by Communities
widgets:
Message | Cause | Solution |
---|---|---|
CLFWZ0001E: Failed to initialize widget lifecycle event propagater. | The widget life-cycle framework failed to initialize. | Validate widgets-config.xml settings. Report this problem to Customer Support. Additional information relating to the failure may be found in the SystemOut.log file. |
CLFWZ0002E: Failed to handle posted lifecycle event. | An application that maintains widget data failed to process a change in the containing community. | Examine the logs for further information. If no resolution is evident, report this problem to Customer Support. |
CLFWZ0003E: Failed to post event notification to remote widget application handler: {0} | Communities was unable to notify a remote application of a community change. | Communities will automatically retry to send the event at a later time. Check log files for any blocking problems in the remote application. |
CLFWZ0004E: Event '{0}' sent to remote lifecycle handler at {1} returned bad response: {2} | Communities was unable to notify a remote application of a community change. | Communities will automatically retry to send the event at a later time. Check log files for any blocking problems in the remote application. |
CLFWZ0005E: Failed to propagate event to widget application handler: {0} | Communities was unable to notify a remote application of a community change. | Communities will automatically retry to send the event at a later time. Check log files for any blocking problems in the remote application. |
CLFWZ0006E: Local widget application handler failed: {0} | Communities was unable to notify forums, bookmarks, or feeds of a community change. | Examine the logs for further information. If no resolution is evident, report this problem to Customer Support. |
CLFWZ0011E: Failed to load widgets-config.xml: {0} | The application was unable to read widgets-config.xml. | Ensure the widgets-config.xml file exists in the LotusConnections-config directory, and ensure that it has the file permissions set so that the IBM WebSphere® Application Server process can read it. |
CLFWZ0012E: Failed to queue event for replay: {0} | A remote application could not be notified of a change in a community. The widget framework could not write an event record for this change so that it can be replayed in the future. | Report this problem to Customer Support. Additional information relating to the failure may be found in the SystemOut.log file. |
CLFWZ0013E: Adding new {0} content is blocked until processing of prior content has completed for resource {1}. Try adding the content at a later time. | A community owner tried to add a new widget to a community but the framework blocked the action because a prior widget of the same type has unprocessed life-cycle events. | Process the life-cycle events for that community. For more information about processing the life-cycle events that occur within a community, see Administering community queued events. Once the queued events for that community have been processed or cleared, the new widget can be added. |
CLFWZ0014E: The remote application {0} does not support being reassigned or transferred to another resource | A wsadmin command for transferring a remote applications was run on a remote application that does not support that function. | The transfer commands are only supported for the Blogs, Activities, Files, and Wikis remote applications. |
CLFWZ0015E: No widget definition found with a definition id of '{0}' | A wsadmin command was run with an invalid definition ID specified. | Rerun the command with the correct definition ID - these IDs are case sensitive. |
CLFWZ0016E: Can not assign to resource with id {0}. Resource already has its unique instance of {1}. | A wsadmin command for transferring a remote application was run that would result in two unique widget instances contained in the same community. | Choose a different community as the destination or delete the blocking unique instance widget. |
CLFWZ0017E: Resource with id {0} was not found. | A wsadmin command was run with an invalid community UUID specified. | Rerun the command with the correct community UUID. |
CLFWZ0018E: Widget with instance id {0} was not found. | A wsadmin command was run with an invalid widget instance ID specified. | Rerun the command with the correct widget instance ID. |
CLFWZ0019E: Only one instance of that widget content can be added. | A second instance of widget was added for a widget type that only allows one widget per community. | Make use of the existing widget or use a different community if necessary. |
CLFWZ0020E: Operation failed because the user is no longer logged in. | A widget action failed because the user is no longer logged in. | Log in and repeat the action. |
CLFWZ0021E: Operation failed because the user lacks the permissions to perform that change. | A widget action failed because the user lacks privileges. | Ask a community owner to make you an owner or to perform the action for you. |
CLFWZ0022E: Operation failed because a remote system was not available. | A widget action failed because a remote application that hosts widget content is not running or otherwise available. | Contact a system administrator to have the remote application restarted. |
CLFWZ0023E: Unable to authorize user for this service. Please contact your system administrator. | A widget action failed because Communities was unable to authenticate the current user. An HTTP 401 status message was returned by the remote application. | Examine logs for further information. Either a legitimate authentication error has occurred with the remote application or it is offline. |
CLFWZ0024E: The server is currently unavailable, either due to overloading or temporary maintenance. Please try again later or contact the administrator. | A widget action failed because the remote application is unavailable. An HTTP 503 status message was returned by the remote application. | Contact your system administrator. |
CLFWZ0025E: Server configuration error. Please contact your system administrator. | A widget action failed because the remote application is unavailable. An HTTP 404 status message was returned by the remote application. | Contact your system administrator. |
CLFWZ0026E: An unexpected error has occurred. Please contact your system administrator. | A widget action failed because an unexpected error occurred. An HTTP 500 status message was returned by the remote application. | Examine logs for further information. Contact your system administrator. |