Performing the upgrade

You can upgrade the Dynamic Workload Console using the following methods:

Interactive wizard

To upgrade using the interactive wizard, run the setup for the operating system on which you are installing:

On Windows operating system:
WINDOWS\SETUP.exe

Before beginning, stop the appserverman process by running the following commands:

Shutdown.cmd -appsrv
StartWas.bat -direct

After running these commands, verify that all Tivoli Workload Scheduler processes are stopped with the exception of the embedded WebSphere Application Server. The embedded WebSphere Application Server must remain running.

On UNIX and Linux operating systems:
SETUP.sh or operating_system/SETUP.bin.
Note:
SETUP.sh copies the entire image to a temporary directory. Ensure there is enough space available.
Launchpad
Start the launchpad and select the Dynamic Workload Console upgrade. The installation wizard is launched with some options pre-selected to upgrade the console.
Silent
You can run the upgrade silently and in background by creating a response file from the template provided and running the installation wizard with the -silent option. See Performing a silent installation for more details on how to run a silent installation or upgrade. See the following section for the upgrade information that you must supply in the response file.

Follow the installation panels to complete the upgrade. The following list describes the fields you must provide during the upgrade.

Use an existing instance of the Dynamic Workload Console
When you are prompted that a previous version of the Dynamic Workload Console has been found, select Use an existing instance. From the drop-down list, choose the instance that you are upgrading.
Administrative credentials of application server
Enter the external or embedded WebSphere Application Server user name and password.
Backup directory
Choose a backup directory. This directory contains only configuration information and other program-related objects and not the external or embedded WebSphere Application Server files. Note that this directory remains on your computer even after the upgrade is complete.
IPC connector
The IPC connector on the portal. The default value is 29314.
REST notification
The REST notification port on the portal. The default value is 29324.
DCS Unicast port
The DCS Unicast port on the portal. The default value is 29353.

|

|
|
Notes:
|
    |
  1. For information about Tivoli Workload Automation instances, see Instances of Tivoli Workload Automation.
  2. |
  3. During an upgrade on Windows, |the embedded WebSphere Application Server Windows Service |account name in the local OS user registry is changed to the administrator |user name of the Tivoli Integrated Portal. If you use a custom registry or LDAP registry, |the service is upgraded to the installation user.
  4. |
  5. It is not necessary to manually stop the embedded WebSphere Application Server prior to upgrading, |as it is stopped automatically during the upgrade procedure.
  6. |