z/OS connector installation |step hangs while installing on a TWA instance with an existing embedded WebSphere Application Server

|

You might run into the following problem when you install Tivoli Workload Scheduler for z/OS connector under |the following conditions:

| |

The step that installs Tivoli Workload Scheduler for z/OS connector hangs indefinitely because the WebSphere Application Server start |timeout is exceedingly short. When this happens, do the following:

|
    |
  1. Kill the WebSphere Application Server process if it is still hanging.
  2. |
  3. Remove, if present, the installed ZOSResourceAdapter.rar client: |
      |
    • On Windows: |
      eWAS_installation_directory\bin\clientRAR.bat delete ZOSResourceAdapter.rar
    • |
    • On UNIX and Linux: |
      eWAS_installation_directory/bin/clientRAR.sh delete ZOSResourceAdapter.rar
    |

    If the command returns an error related to the inexistence |of ZOSResourceAdapter.rar, ignore the error and continue.

  4. |
  5. Rerun the failed installation step.