IBM Integration Bus, Version 9.0.0.8 Operating Systems: AIX, HP-Itanium, Linux, Solaris, Windows, z/OS

See information about the latest product version

Resequence configurable service

Select the objects and properties that you want to change for the Resequence configurable service.

For Resequence configurable services, you must stop and start the integration server for a change of property value to take effect.

Supplied configurable services that are created for each broker Properties for each configurable service that is defined Description of properties
None queuePrefix

The queue prefix used to specify the storage queues that are generated for use by the Resequence node. This property is optional.

Two queues are required:
  • SYSTEM.BROKER.EDA.QueuePrefix.EVENTS
  • SYSTEM.BROKER.EDA.QueuePrefix.COLLECTIONS

The prefix can contain any characters that are valid in a WebSphere® MQ queue name, but must be no longer than eight characters and must not begin or end with a period (.). For example, SET.1 is valid, but .SET1 and SET1. are invalid. Multiple configurable services can use the same queue prefix.

If no queue prefix is specified, the Resequence node uses the default queues that are generated when the broker is created:
  • SYSTEM.BROKER.EDA.EVENTS
  • SYSTEM.BROKER.EDA.COLLECTIONS
These default queues are also used by the Collector node.
missingMessageTimeoutSeconds

The value used by the Resequence node to specify how long the node waits for the next message in a sequence before it is propagated. The value can be any integer that is greater than 1.

The value of this property (if it is set) overrides the value set on the node.

This property is optional; if it is not set, the value set on the node is used.

startSequenceSeconds

The value used by the Resequence node to specify how long the node waits before calculating the start number in a sequence of messages. The value can be any positive integer.

This value is used only if the Start of sequence property of the Resequence node is set to Automatic.

The value of this property (if it is set) overrides the value set on the node.

This property is optional; if it is not set, the value set on the node is used.

endSequenceSeconds

The value used by the Resequence node to specify how long the node waits for the next message in the sequence to arrive before it closes the sequence. The value can be any positive integer.

The value of this property (if it is set) overrides the value set on the node.

This property is optional; if it is not set, the value set on the node is used.


bn28741_.htm | Last updated Friday, 21 July 2017