IBM Integration Bus, Version 9.0.0.8 Operating Systems: AIX, HP-Itanium, Linux, Solaris, Windows, z/OS

See information about the latest product version

MonitoringProfiles configurable service

Select the objects and properties that you want to change for the MonitoringProfiles configurable service.

Supplied configurable services that are created for each broker Properties for each configurable service that is defined Description of properties

DefaultMonitoringProfile

profileProperties

The name of the monitoring profile. The monitoring options defined by the monitoring profile can be configured with an XML file that conforms to the monitoring profile schema.

useParserNameInMonitoringPayload

When the payload is included in a monitoring message, setting this property to TRUE forces the wmb:applicationData/wmb:complexContent/wmb:elementName attribute to contain the name of the input node parser if present.

This property is optional. Valid values are TRUE and FALSE. The default value is FALSE, which means that the wmb:applicationData/wmb:complexContent/wmb:elementName attribute contains the MessageType property value.

Setting this property on the default monitoring profile affects the behavior for all nodes that are not explicitly using configurable services.


bn28737_.htm | Last updated Friday, 21 July 2017