Handling timeout notification errors

The TimeoutNotification node takes various actions when it handles errors with transactional messages, depending on whether the Failure and Catch terminals are connected.

Errors that are encountered with non-transactional messages are handled as described in Managing errors in the input node.

This action is summarized in the following table.

Error event Failure terminal connected Failure terminal not connected Catch terminal connected Catch terminal not connected
The node detects an internal error. The flow that is connected to the Failure terminal handles the error. The error is logged and the node retries the operation. Not applicable Not applicable
The node propagates a message to the Out terminal and an exception occurs in the output flow. Not applicable Not applicable The flow that is connected to the Catch terminal handles the error. The error is logged and the node retries the operation.
The node propagates a message to the Catch terminal and an exception occurs in the flow that is connected to the Catch terminal. The error is logged and the node retries the operation. The error is logged and the node retries the operation. Not applicable Not applicable
The node propagates a message to the Failure terminal and an exception occurs in the flow that is connected to the Failure terminal. Not applicable Not applicable The error is logged and the node retries the operation. The error is logged and the node retries the operation.