Subparameter definition

overlay-name
Identifies the forms overlay frame that the operator is to insert into the printer before printing begins. The name is 1 through 4 alphanumeric or national ($, #, @) characters.
count
Specifies the number, 0 through 255, of copies that JES is to flash with the overlay, beginning with the first copy printed. Code a count of 0 to flash no copies.
NONE
Suppresses flashing for this sysout data set.

If FLASH=NONE is on an OUTPUT JCL statement in a job to be executed at a remote node, JES3 sets the overlay-name to zero before sending the job to the node.

STD
Indicates the standard forms flash overlay. JES3 uses the standard forms overlay specified at JES3 initialization.
Note: STD is supported only on JES3 systems.